OPERATION: USER INTERFACE
MVS Series
33
710-03261-00D
•
Signalling Simulation
The MVS Controller allows the user to simulate output signalling in order to confirm
that the outputs are operating correctly.
NOTE
During the simulation, no pre-start checks are made and the soft starter
must be disconnected from mains voltage. The MVS Controller must be
connected to the low voltage control supply.
The simulation is only available when the soft starter is in Ready state.
To activate the signalling simulation:
1. Open the Commissioning Menu and select Signalling Simulation.
Simulation Mode
Output Signal Sim >
2. Press
the
►
button to open the simulation list. The display will indicate the first
simulation in the list.
Analog Output
Simulate
>
3. Use
the
▲
and
▼
buttons to select a simulation. The following signals are
available to simulate:
Analog output
Low current flag
1
High current flag
1
Motor temperature flag
1
Relay A
Relay B
Relay C
1
To test the flags, set an output relay (parameters 5-A to 5-C) to the
appropriate function and monitor the relay's behaviour.
4. Once the required simulation is displayed, press
►
to confirm the selection.
Low Current Flag
Simulate
>
5. Press
the
▲
button to start the simulation. Pressing the
▼
button stops the
signal.
Low Current Flag
▲
On
▼
Off
While the signal is being simulated, the display will indicate On. While the
signal is not being simulated, the display will indicate Off.
6. Once the simulation is complete, press
◄
to return to the simulation list.
Press
▲
or
▼
to select another simulation, or press
◄
again to return to the
Commissioning Menu.
Analog Output Simulation
The analog output simulation uses the
▲
and
▼
buttons to change the analog
output current at terminals B10, B11 of the MVS Controller.
Analog Output
0% 4
mA
Attach an external current measuring device to terminals B10, B11 of the MVS
Controller. Use the
▲
or
▼
button to adjust the percentage value in the lower left
hand corner of the display. The current measuring device should indicate the
same level of current as shown at the lower right corner of the display.
Содержание MVS0080
Страница 1: ...G U I D E MVS SERIES SOFT STARTERS PRODUCT ...
Страница 22: ...INSTALLATION CONTROL CIRCUITS MVS Series 21 710 03261 00D 6 2 Internal Wiring Diagram 4 Internal Wiring ...
Страница 42: ...OPERATION OPERATION MVS Series 41 710 03261 00D Diagram 5 Slip Ring Motor Connection ...
Страница 52: ...NOTES MVS Series 51 710 03261 00D ...
Страница 53: ...NOTES 710 03261 00D 52 MVS Series ...