background image

 

 

Figure 7. Connection between the controller and smoker 

 

2) Connection for Bradley Digital Smoker. 

For the Bradley Digital Smoker, both controller and smoker generator should be 
connected directly to the wall outlet. Connect the controller output with the smoker tower. 

Auber

Controller

Smoke

Generator

Smoker Tower

Probe 1: 

Cabinet Temp

Probe 2: 

Internal Temp

C

ab

le

 C

Cable B

To Power Outlet

To Power Outlet

 

Figure 8. Connection for Bradley Digital Smoker   

Cable C is extra 18 AWG power cord, same as Cable B 

Содержание WSD-1501GPH

Страница 1: ...is plug and play controller is very easy to operate the process involves high temperature and high wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed only to b...

Страница 2: ...or low limit alarm of probe 1 is on this window will flashing between the alarm type AH1or AL1 and the temperature In the parameter setting mode it displays the controller s system parameters 2 TEMP2...

Страница 3: ...he parameter setting mode During normal operation press it to cancel the alarm 8 Key To increment displayed value when in controller is in the parameter setting mode During normal operation press it w...

Страница 4: ...enough so that it does not touch the food See Error Reference source not found The tip of probe 2 is to be inserted into the meat Figure 3 Sensor position Left the sensor should be placed close to the...

Страница 5: ...outlet you should use the power cord that came with the Bradley Smoker for connecting the smoker generator to the power outlet b Connecting the controller to the smoker generator You should use the p...

Страница 6: ...the Bradley Smoker Tower with the power cord that came with the Auber Controller Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal Temp Cable A Cable B To Power Outl...

Страница 7: ...oker generator should be connected directly to the wall outlet Connect the controller output with the smoker tower Auber Controller Smoke Generator Smoker Tower Probe 1 Cabinet Temp Probe 2 Internal T...

Страница 8: ...l show C 1 at the left window and temperature setting on the right window for step 1 Use and keys to change the setting When finished press the SET again to confirm the change The display will show E...

Страница 9: ...e To check which step the program is at during cooking press the Key 8 once The left window will show the current step in the form of P0X on e g It will display P03 if the controller is at step 3 The...

Страница 10: ...ter in the smoker c Damper position Keeping the damper open will result in better temperature stability because more heat loss is created This is important when the temperature is set below 140 F When...

Страница 11: ...1 this is the high limit alarm for probe 1 User can set the temperature so that if the system is out of control the buzzer will be turned on e g If AH1 set to 290 the buzzer will be on at 291 and off...

Страница 12: ...ht window will show 0 Use the or key to adjust the value to 2 the passcode for saving the program and then press SET key to confirm Then SAV will be shown on the left window and End on right window If...

Страница 13: ...exit In single step mode the save and recall function Section 9 can still work But the change can only be applied to C 1 i e you can only store your current set temperature to the C 1 in a selected r...

Страница 14: ...o confirm and exit Now the C 1 from the recipe b2 is recalled back to your current program The controller will start run at this temperature setting e Advanced example This example will show you how t...

Отзывы: