background image

 
 

 

 
 

design for kitchen applications, the controller has a limited ability to dissipate the 
heat generated by the internal solid state relay during the initial heat up process. 
The initial full power heat up process cannot be more than 90 minutes. If you have 
a pot that is larger than 

5 gallons (19 litters), please read Appendix 1 “Managing 

the heat generated by the controller

” 

  Always place the sensor in the controlled subject when the controller is on. Before 

turning on the controller, please make sure the sensor is placed inside the 
container to be controlled. Leaving the sensor outside of the solution will form an 
open loop operation. If the sensor is left outside, controller will assume the 
temperature is low even if the controlled subject is already very hot. The controller 
will provide full power to the heater which will not only overheat the controller but 
also damage your appliance, possibly causing a fire.   

  The 16 AWG power cord provided with your controller is specially designed for 

high power applications. Do not replace it with a regular computer power cord 
when the heating/cooking device is more than 1200 watts. 

  This controller is designed to control the devices recommended by Auber 

Instruments only. Using it to control a not recommended device can be dangerous 
and cause fires. Auber Instruments is not liable for damages caused by misuse of 
the controller. If you are not sure the controller can be used, please contact Auber 
Instruments before use. 

  If an abnormal display or noise is observed, turn the controller off, unplug the 

power cord and contact the manufacturer before using it again. 

  Clean the controller only when it is cool and unplugged. 

  Do not allow children to operate the controller.   

Specifications 

Input voltage:

   

100 to 240 VAC 50 /60 Hz 

Output voltage:

   

Same as the input.   

Maximum Current:

   

12A at 120V, 10A at 240V 

Fuse Size:

 

15A Fast blow. 

Controller Mode:

   

PID, PI, PD or P. 

Output switching device:

    Built-in optically isolated solid state relay with zero voltage 

crossing switching.   

Sensor tip dimensions:

   

4 mm diameter x 40 mm long.   

Sensor cable length:

 

5 ft (1.5 m) 

Timer Range:

 

0.1 to 99.9 hours for each step, 6 steps total 

Temperature resolution:

   

1 °C or 1 °F 

Temperature display range:   

-10 to 200 °C or 14 to 392 ° F 

Temperature control range:

 +5 °C (°F) from room temperature to 195 °C (383 °F) 

Temperature accuracy:

   

±1°C (±2°F)   

Dimension:

   

6.5 x 3 x 5.2 inch (170 x 80 x 135 mm) W x H x D. 

Содержание WS-1200CPH

Страница 1: ...ery easy to operate the process involves high temperature and high wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed only to be used with devices that have li...

Страница 2: ...king device is more than 1200 watts This controller is designed to control the devices recommended by Auber Instruments only Using it to control a not recommended device can be dangerous and cause fir...

Страница 3: ...of local standard is needed Operating Instructions 1 Description of the controller Fig 1 Front Panel 1 Parameter Window LED for displaying temperature values and controller s system parameters 2 Outp...

Страница 4: ...layed in the Parameter Window is time passed since power up If it is flashing but Timer Status Indicator 8 is off the value displayed in the Parameter Window is the parameter that needs to be set The...

Страница 5: ...Each step contains the temperature C0X and time duration T0X setting They are represented by the symbol C0X and T0X where X is the step number e g Step 4 temperature is represented by C04 and step 4...

Страница 6: ...eps for cooking you can finish programming by pressing the SET continuously until it passed T06 and displays the current temperature You can also leave the controller alone The display will return to...

Страница 7: ...en on e g it will display t03 for a second if the controller is in step 3 of cooking When 8 is on lit and 7 is flashing at the same time LED is in timer mode and shows the actual time passed since the...

Страница 8: ...d how efficiently it transfers heat For example consider the difference between a heat lamp and a hot plate When electricity is applied to a heat lamp it begins to heat instantaneously and when it s t...

Страница 9: ...ely between A and the current water bath temperature which indicates auto tuning is in progress When the display stops flashing the auto tuning is finished Now the newly calculated PID parameters are...

Страница 10: ...8 when changing the temperature unit to Fahrenheit I Integral time The unit is in seconds This parameter controls the output of the controller based on the difference between the measured and set tem...

Страница 11: ...e SET again to confirm the change The display will show the d for a second and its value next Use the same P setting procedure to set the d value When finished press the SET again to confirm the chang...

Страница 12: ...optimized temperature control system should consume about 25 of the heater power at the set temperature steady state For example if you found out that only 50 watts of energy is needed to maintain the...

Страница 13: ...offset value Setting the output reduction The parameter window will first show OUt for a second and then its value Use and keys to change OUt value to your desired limit value and press SET Setting C...

Страница 14: ...rranty does not cover damage caused by misuse abuse negligent handling or damage due to faulty packaging or mishandling in transit This warranty does not cover damage or defects caused by or resulting...

Страница 15: ...re the package as damage in shipping is not covered by your warranty Mark the outside of your package ATTENTION CUSTOMER SERVICE We are constantly striving to improve our products and therefore the sp...

Страница 16: ...l produce about 1 3 watts of heat When 12 Amps is passing through the controller 16 watts of heat is produced in the controller As more heat is produced the temperature inside the controller will rise...

Страница 17: ...ctive current is much lower making heat not an issue 2 Limit maximum output power If you set output reduction parameter to 80 then a 15 A heater will become a 12 A heater It will take 25 longer time t...

Страница 18: ...ontroller and smoker The input of the controller is connected to the power strip by the 16 AWG power cord supplied blue arrows The generator is connected to the power strip by the power cord from Brad...

Страница 19: ...by the power jumper cord provided by the Bradley blue arrows It is the cord that used to connect the generator to smoker The controller output is connected to the smoker by the power cord red arrows I...

Страница 20: ...ossible This is especially the problem for the Bradley Original Smoker because of its black color The controller should be placed away from direct sun light also Although the controller uses a high in...

Страница 21: ...hotter if more food is placed in it to block the hot air from going up e Operating the controller when ambient temperature is below 32 F 0 C The controller reading is only accurate for temperature 32...

Отзывы: