Auber Instruments SYL-2615 Скачать руководство пользователя страница 2

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2019.07                                                                     

   

                                                       P2/7 

 

 Probe 2 input for Food temperature. 

 Power output for fan control.  

 Power input for controller (12 VDC). 

 

4. LCD Display Modes 

       Time:
                    0:15

 

|

 

Press 

Momentarily

Pit: 73    Set:225

Food:71    Out:99

Normal Display

>Step: 1  Pit: 225
  Back

SET

Press 
Momentarily

> Control  config
   System config

Time Checking

Cooking Profile

Parameter Settings

SET

Press & Ho

ld

Time: 0:02/ 9:00
Tot: 0:10 Step: 2

OR

Time Checking

 

Figure 2. Switching between different display modes. 

 

4.1 Normal Display Mode 

 

Pit: 73    Set:225

Food:71    Out:99

 

 

 

 

 

 

Figure 3. Information displayed on the LCD in the normal operating mode. 

 

 Pit temperature 

 Food temperature  

 Set value for pit temperature 

 Output power (percentage) 

 
 

4.2 Time-Checking Mode 

 

       Time:
                    0:15

Pit: 73    Set:225

Food:71    Out:99

 

|

 

Press

Time: 0:02/ 9:00
Tot: 0:10 Step: 2

Pit: 73    Set:225

Food:71    Out:99

 

|

 

Press

 

Figure 4. Using Timer/Back key to check cooking time in single-step mode 

(left) and in multi-step mode (right). 

 

Press the Timer/Back key can tell you the current timer and step information. 
In single step mode, press timer key will show the total running time after your 
powered this controller up this time. In multi-step mode, pressing timer key will 
display more information, including the elapsed time for current step and total 
time for current step (first line); total elapsed time and current step number 
(second line). 
 
This key has two more functions: a) Press it in the parameter setting mode will 
return back to the upper level menu. This provide a short cut to exit the current 
menu. b)  Cancel the open lid detection. For details, please see Note 8 in 
section 6.2.2.  
 

4.3 Cooking Profile Programming Mode 

The controller’s cooking profile can be 

either set to single-step mode (default) 

or set to multi-step mode. In the single-step mode, the controller will try to 
maintain the pit temperature at the set value of Step 1 as long as the controller 

is on. In the multi-step mode, up to 3 steps can be programmed. Each step 
has its own set temperature for pit probe, and its step-ending criterion. A 
cooking step can either end by timer or by food temperature. For details, 
please check section 6.1. 
 

4.4 Parameter Setting Mode 

> Control  config
   System config

Pit: 73    Set:225

Food:71    Out:99

SET

Press and hold

 

Figure 5. Access the menu of parameters using SET key. 

 

5. Getting Started  

Power on the controller by plugging the barrel connector from the 12 VDC 
adapter to the power input port 

. Connect the pit probe (probe 1) to socket 

, food probe (probe 2) to socket 

. Configure the Wi-Fi connection from 

your phone using AuberSmart app*. After you have set up the controller and 
started fire in your smoker or grill, mount the blower to the smoker/grill, then 
plug the blower connector to the fan output port 

 

 
Note *: Please check the supplementary manual for Wi-Fi configuration and 
how to use the AuberSmart app.  
 

6. Operation 

All cooking profile settings and control parameters can be accessed both from 
the device and from the AuberSmart app.  
 

6.1 Set the Cooking Profile 

Th

e controller’s cooking profile

 can be either set to single-step mode (default) 

or set to multi-step mode. In the single-step mode, the controller will try to 
maintain the pit temperature at the set value of Step 1 as long as the controller 
is on. In the multi-step mode, up to 3 steps can be programmed. Each step 
has its own set temperature for pit probe, and its step-ending criterion. A 
cooking step can either end by timer or by food temperature. To switch 
between single-step mode and multi-step mode, please check section 6.1.3.  
 

6.1.1 Single-Step Mode 

In this mode, you can only access and change the target pit temperature of 
Step 1 from the device. The controller will try to maintain the smoker 
temperature at the set temperature of Step 1 continuously as long as the 
controller is powered on. If this controller is powered off and turned back on 
again, it will resume operating in this mode. You can still view and change 
other settings in Cooking Profile 

from the app, but they don’t apply to this 

mode. 
 
To change the set temperature in single-step mode, press SET key once, it 

will show “Step: 1” and the current target pit temperature in the top line. A 
curser “>” will be shown on the left indicating which line 

will be selected. Press 

SET key once, the current set temperature should start blinking. Use 

 and 

 keys to change the set temperature. When finished, press the SET again 

to confirm the change. That number will stop blinking. Press the Timer/Back 
key to exit the menu. Or use 

 or 

 key to scroll to 

Back

 and then press 

SET key to exit. The display will return to the normal display mode if no key is 
pressed in 14 seconds. 
 

Содержание SYL-2615

Страница 1: ...of which the cooking time is unknown it is better to set a target food temperature to end the step SYL 2615 has a build in Wi Fi module which allows its user to monitor the temperature and control the...

Страница 2: ...ut 99 SET Press and hold Figure 5 Access the menu of parameters using SET key 5 Getting Started Power on the controller by plugging the barrel connector from the 12 VDC adapter to the power input port...

Страница 3: ...N A In this example a user set the pit temperature of Step 1 to 275 F which is higher than normal smoking temperature to speed up the low and slow cooking without compromising the moisture Step 1 wil...

Страница 4: ...2 WSM18 4 5 6 Back 9 Recall Recall PID Settings Back BGE WSM22 WSM18 4 5 6 Back 9 Back Back to main menu Control config System config AH Pit 350 AL Pit 0 AL Pit 0 AH Food 350 Back AH Pit 250 SET SET A...

Страница 5: ...he rate of change rather than the net amount of change This will allow the controller to act sooner It will turn the heater to full power before the temperature drops too much Note 7 T Control Cycle T...

Страница 6: ...manually adjust the fan speed output voltage Note 12 FMRV Fan minimum running voltage This parameter is only used when controller is running under fan speed control mode Due to the variation in the fr...

Страница 7: ...on the probe your probe is bad If this issue remains on the controller your controller is bad For more details please contact customer support 8 2 What if one step is set to end by food temperature w...

Отзывы: