background image

         AUBER INSTRUMENTS

  

 

 

 

 

 

 

 

         

WWW.AUBERINS.COM  

 

 

         2021.10                                                                    

   

                                                       P4/6 

 

PV

SV

SV-Hy

100

97

Relay On

When heating, and outy = 3 or 4,
If PV 

 

 (SV - Hy), relay on

If PV 

 

 SV, relay off

(SV = 100, Hy = 3)

Table 4. Temperature and alarm parameters 

Symbol 

Description 

Initial 

Setting 

Note 

SV 

SV 

Target temperature  

(Set Value) 

800 

12 

AH1 

AH1 

J1 on temperature 

800 

13 

AL1 

AL1 

J1 off temperature 

900 

  

AH2 

AH2 

J2 on temperature 

800 

  

AL2 

AL2 

J2 off temperature 

900 

  

END 

END 

Exit 

  

  

 

Note 12. 

There are two ways to set the target temperature: 

 
a.

 During the normal operation mode, press ^ or V keys once to switch the 

display from PV to set value. The display will start to blink. Press ^ or V keys 
again to increase or decrease the SV. When finished, wait 8

 

seconds and the 

settings will take effect automatically (the display will stop blinking). 

 
b.

 Press SET key once. Use >, ^ and V keys to enter code 0001. Press SET key 

to confirm, then the display would be SV (

Su

). Press SET key again to display 

the SV setting. Use >, ^ and V keys to enter the new SV value and press SET 
key to confirm. Press V key to change the display to END. Then, press SET key 
to exit. You can also ignore the steps after confirmation of SV. The controller will 
returns to normal operation mode automatically if no key is pressed for 1 minute. 
This method is easier for large temperature change. 
 

Note 13.

 Alarm setting. The J1 relay is controlled by parameters AH1 and AL1. 

And the J2 relay is controlled by parameter AH2 and AL2.  AH1 (or AL2) is the 
temperature to turn the J1 (or J2) relay on; AL1 (or AL2) is the temperature to turn 
the J1 (or J2) relay off. When AH1>AL1 (or AH2>AL2), the J1 (or J2) alarm is set 
for  absolute  high  alarm  as  shown  in  Figure  5  below.  When  AH1  <AL1  (or 
AH2<AL2), the J1 (or J2) alarm is set for absolute low alarm as shown in Figure 6 
below. When AH1=AL1 (or AH2=AL2), the J1 (or J2) alarm is deactivated. 
 
Please note that 

J2 can’t be used as alarm when “

outy

 is set to 1, 4 or 5. 

 

Relay on

Relay on

PV

PV

Figure 5. Absolute high alarm

Figure 6. Absolute low alarm

SV

AL1

AH1

AH1

AL1

SV

 

 

6. Auto-Tuning

 

 

The Auto-tuning function (also called self-tuning) can automatically optimize the 
PID parameters for the system. The auto-tuning function will use the On/off mode 
to heat up the system until it passes the set point. Then let it cool down. It will 
repeat this about three times. Based on the response time of the system, the built-
in artificial intelligence program will calculate and set the PID parameters for the 
controller. If your system has a very slow response, the auto-tuning could take a 
long time. 
 
 
 
 
 

AT start

AT calculation

AT end

ON OFF

ON OFF

ON/OFF

PID 

SV

PV

 

Figure 7. Auto-tuning 

 
6.1 

To activate Auto-tuning, press and hold > 

key until the “AT” indicator starts to 

blink, which indicates auto-

tuning is in progress. When “AT” stops 

blinking, the 

auto-tuning is finished. Now, newly calculated PID parameters are set to be used 
for the system. Please note that Auto-tuning is only for PID control mode (when 

“outy”

 is set at 1 or 2). 

 

6.2 

To stop the Auto-tuning, press and hold > key unti

l “AT” indicator stops blinking. 

Then, the previous PID parameters values are resumed. 
 

7. On/off control mode  

On/off  control  mode  is  not  as  precise  as  PID  control  mode.  However,  it  is 

necessary for inductive loads such as motors, compressors, or solenoid valves 
that do not like to take pulsed power. It works like a mechanical thermostat. When 
the temperature passes the set point, the heater (or cooler) will be turned off. When 
the temperature drops back to below the hysteresis band (dead band) the heater 
will be turned on again.  
To use the on/off mode, set Outy to 3 or 4 depending on the output device to be 
used.  Then,  set  the  Hy  to  the  desired  range  based  on  control  precision 
requirements.  Smaller  Hy  values  result  in  tighter  temperature  control,  but  also 
cause  the  on/off  action  to  occur  more  frequently.  In  the  PID  parameters  menu 
(code 0036), only ot and FILt are used. P, I, D and SouF are not meaningful. 
 
 
 
 
 
 
 
 

 

Figure 8. On/off control mode 

 
 

8. Manual mode

 

Manual mode allows the user to control the output as a percentage of the total 
heater power. It is like a stove dial. The output is independent of the temperature 
sensor  reading.  One  application  example  is  controlling  the  strength  of  boiling 
during beer brewing. You can use the manual mode to control the boiling so that 
it will not boil over to make a mess. The manual mode can be switched from PID 
mode but not from On/off mode. To switch from the PID to the manual mode, press 
and hold the SET key until the 

AT/M

 indicator turned on (about 5 seconds). In 

the manual mode, the top display is for the process temperature. The bottom right 
is the percentage of power output. The bottom left display show an 

M

 for user 

to easily identify the controller is in manual mode. To switch from manual to PID 

Отзывы: