TI034-3W
400-034-001-D 13/3/07 1/2
The TI034-3W switch can be used in a single-pole or 3-way installation with the fol-
lowing types of lighting:
• Incandescent
• Halogen
• Low-voltage halogen with transformer
• Fluorescent
The TI034-3W switch cannot be used with a load below 40 W or above 500 W.
n
Cut power at the circuit breaker to avoid electric shock.
o
Remove the existing switch. (For a 3-way installation, identify and label the
wire that is connected to the “common” screw.)
p
Install the new switch (refer to the appropriate section below).
q
Apply power at the circuit breaker.
SINGLE-POLE INSTALLATION
Connect wires "2" and "C" of TI034-3W to the line (120 V) wire.
EXISTING 3-WAY INSTALLATION
Connect wire "C" on the TI034-3W to the "common" wire, identified when removing the
old switch. Connect the other two TI034-3W wires to the two remaining wires.
At the other 3-way switch, connect the jumper wire between the "common" screw and the
screw where wire "1" of the TI034-3W is connected.
NEW 3-WAY INSTALLATION
The jumper wire is not required in this installation. A single-pole switch can be used as
the other switch in a 3-way installation.
n
Pry the switch door open from the bottom
using a small screwdriver.
o
Ensure the
ON/OFF
selector is set to ON.
p
Reset the switch using a paper clip.
0:00
will
flash.
If the display is blank:
•
Ensure the
ON/OFF
selector is properly
engaged in the
ON
position. Push it to the right
using a small screwdriver.
•
If the programmable switch controls a lamp equipped with a built-in On/Off switch,
ensure the lamp switch is set to On.
•
Ensure the light bulb is not burned out and is tightly screwed in its socket..
EXISTING 3-WAY INSTALLATION
If either switch does not work properly, rewire the jumper between the "common"
screw and the other screw.
WARNING
: Before replacing the light bulb, place the
ON/OFF
selector in the
OFF
position. Failure to do so might damage the switch.
The programmable switch has 2 operating modes: manual (
MAN
) and automatic
(
AUTO
). To switch mode, press the switch for 3 seconds.
Manual Mode
The programmable switch operates as a regular switch. Briefly
press the switch door to turn the lights On or Off. The mode
(
MAN
)
and state (
ON
or
OFF
) are displayed.
Automatic Mode
The programmable switch follows the programmed schedule.
The mode (
AUTO
), state (
ON
or
OFF
) and current program
number are displayed.
To temporarily override the programmed schedule, briefly
press the switch door. The new state (
ON
or
OFF
) will flash to
show that the state is temporary. The override remains in effect
until you press the switch door again or until the beginning of
the next program.
NOTE
: The switch displays the time in 24-hour format by default or following a
reset.
n
To switch between 12-hour format and 24-hour format, proceed as follows:
a)
Press one of the control buttons to ensure the
MAN
or
AUTO
indicator is dis-
played.
b)
Press the
MIN
and
HOUR
buttons simultaneously and brieftly (
0:00
display =
24-hour;
12:00
display = 12-hour ).
o
Set the time using the
HOUR
and
MIN
buttons. For the 12-hour time format, if you
are setting an afternoon time, ensure
PM
appears on the screen.
p
Press one of the control buttons or close the switch door to return to normal opera-
tion.
This procedure configures the switch in daylight savings time or in normal/standard
time.
n
Press the
CODE
button four times.
o
Press the
MIN
button to switch between
nor
and
Ad
.
p
Press one of the control buttons or close the switch door to return to normal opera-
tion.
n
Applications
1.
o
Installation
2.
NOTE A: The white wire is not the neutral wire but the wire going to the load.
Line
Neutral
See NOTE A
120 VAC
Line
Neutral
120 VAC
Red
Jumper
Red
3-wire cable
See NOTE A
120 VAC
120 VAC
See NOTE A
p
Power-on
3.
q
Selecting the Operating Mode
4.
r
Setting the Clock
5.
s
Daylight Savings Time
6.
nor
Standard time / Normal time / Winter time
Ad
Daylight savings time / Advanced time / Summer time
Control (4)
Reset
On/Off
selector
TI034-3W
Installation and User Guide
Programmable Wall Switch