VG OSG
Version 3
11
Signals
Controller input power supply will be 230V or 110V AC 50/60Hz, it has an internal
12v DC control voltage, power supply and battery backup.
The system requires the following signals and connection to the external
contacts to enable it to operate.
1. Live Supply
2. Neutral Supply
3. Earth
4. A Door Open / Closed Input signal
5. A Main Motor Contactor Open / Closed Signal
6. Main Lift Safety Circuit Output Signal
7. Main Lift Alert/Warning Output Signal
8. Optional hand winding contact
9. Optional test control contact
Handling, Transport
And Storage
The components of this system have been carefully packaged for shipping,
including strapping and strong tape. If you use a knife to cut open the boxes,
please be very careful to ensure that you only cut through the tape and straps
and not through the cardboard potentially damaging the components inside.
Please inspect the components of this system thoroughly prior to attempting to
install it. If any of the components has been or suspected to have been damaged
or exposed to moisture, they should not be used. Please return them to Atwell
International for examination and re-test.
The VG OSG and the VGOSG-CB01 should never be lifted or carried by their
cables. They should never be allowed to get wet or exposed to moisture.