ATTO Technology iPBridge 1550D Скачать руководство пользователя страница 41

xii

SNTPServer

Controls or displays the main IP address the client uses 
to retrieve the SNTP time.

Default: 192.43.244.18
set SNTPServer [xxx.xxx.xxx.xxx]
SaveConfiguration Restart command required
get SNTPServer

SpeedWrite

Improves the performance of SCSI WRITE commands to 
target devices attached to the iPBridge. Specify 

all 

to set 

the Speed Write state for each currently mapped device 
on the iPBridge, or to get a list of the Speed Write states 
of all currently mapped devices on the iPBridge.

Default: disabled
set SpeedWrite SCSI [ sb st sl | all] [enabled | disabled]
get SpeedWrite SCSI [ sb st sl | all]

SpeedWriteDefault

Specifies the default 

SpeedWrite

 state applied to new 

device mappings created manually or using an 

AutoMap

 

operation.

Default: disabled
set SpeedWriteDefault [enabled | disabled]
get SpeedWriteDefault

TailEventLog 

Displays new events to the terminal. Type 

quit

 then press 

ENTER 

to exit tail mode.

TailEventLog

Time

Controls or displays the current time as clocked by the 
iPBridge in 24 hour format. 

set Time [HH: MM: SS]
get Time

TimeZone

Controls or displays the time zone or an offset from GMT.

Default: EST
set TimeZone [[EST | CST | MST | PST] | [[+| -] 

[HH]:[MM]]]

SaveConfiguration command required
get TimeZone

Username

Specifies the user name for all sessions. It is case 
insensitive, 1 to 32 characters, and cannot contain 
spaces.

Default: root
set Username [username]
SaveConfiguration command required
get Username 

VerboseMode

Controls the level of detail in CLI 

Help 

 output and 

command response output for the current CLI session.

Default: enabled
set VerboseMode [enabled | disabled]
get VerboseMode

VirtualDriveResponse

Provides proxy responses to SCSI INQUIRY and TEST 
UNIT READY commands if a SCSI device selection times 
out or has a busy event. Host systems can assign devices 
consistently regardless of the device’s state during the 
execution of the commands.

Default: disabled
set VirtualDriveResponse [enabled | disabled]
get VirtualDriveResponse

VLAN

Sets Virtual LAN ID values for each Ethernet data port. 
Up to 8 IDs can be stored per port. Incoming packets are 
filtered if their tags are not on the list of VLAN IDs for 
that data port. Outgoing packets are tagged to match 
their connection. Each VLAN ID is assigned a VLAN 
name of up to 64 characters. If no VLAN IDs exist for a 
data port, VLAN is disabled for that data port.

set VLAN [dp1] [[VLAN ID] [VLAN Name] <delete> | [all] 

[delete]]

get VLAN [dp1]

Содержание iPBridge 1550D

Страница 1: ...iPBridge 1550D Installation and Operation Manual...

Страница 2: ...chnical support Monday Friday 8am 8pm EST techsupp attotech com 2007 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manua...

Страница 3: ...Setting up Internet Explorer Beginning initial configuration 3 Configure the iPBridge 7 Preliminary steps ExpressWizard 3 1 Target management 9 Target names Default target node Automatically configure...

Страница 4: ...formance issues Check SCSI devices Check the iPBridge SCSI port Check the iPBridge Ethernet port Check the LAN WAN Check the Ethernet Host Adapter or NIC Check the applications Check the host system C...

Страница 5: ......

Страница 6: ...ng your existing storage capacity without sacrificing performance The ATTO iPBridge 1550 is ideally suited to the SME or for corporate IT departments seeking to expand storage requirements with minima...

Страница 7: ...2 Exhibit 1 0 1 Possible storage solutions using the iPBridge...

Страница 8: ...ended SCSI Ethernet port The 10 100 1000 GbE RJ 45 Ethernet port uses the Intel 8254x family gigabit Ethernet chipset to support iSCSI data transfer and inbound management GbE cables must be at least...

Страница 9: ...4 Exhibit 1 1 1 iPBridge 1550D back panel...

Страница 10: ...r the iPBridge Ready LED to light indicating the bridge has completed its power on self test sequence 8 Windows users continue to Installing Windows drivers Mac users continue to Discovering the IP ad...

Страница 11: ...3 Click OK to close the iSCSI Initiator utility You should now have storage you can manage through Windows Disk Management Continue to Beginning initial configuration Installing iSCSI Initiator for Ma...

Страница 12: ...one of three ways Review the settings keeping the automatic settings created when you powered up your iPBridge and do nothing now Use the ExpressWizard accessed from the side menu to initially set up...

Страница 13: ...ed Change any elements as needed 12 Click Next 13 The configuration for the iPBridge based on your input in the previous screens appears If the information is correct click Commit 14 The ExpressWizard...

Страница 14: ...target with Access Control ACL disabled and CHAP authentication disabled The default target node cannot be deleted Use the ExpressNAV interface to map devices automatically or manually Refer to Openi...

Страница 15: ...the ExpressNAV main menu click on the Automatic Target Management menu item on the left side of the screen 3 Click on the Map each device to its own target button A target name suffix is attached to t...

Страница 16: ...11 ATTO Technology Inc iPBridge Installation and Operation Manual Exhibit 3 1 1 Target node configurations...

Страница 17: ...dge will delegate its access control authorization to an iSNS server Default is disabled Note iSNS Login Control cannot be used with Access Control found on the iSCSI Target Management page iSNSServer...

Страница 18: ...ndicated 4 Enter appropriate information into the New Admin Password Confirm New Admin Password or New Read Only Password and Confirm New Read Only Password text boxes 5 Click Submit 6 Go to the Resta...

Страница 19: ...he target during the execution of a single SCSI command including the immediate data and the sequence of unsolicited Data Out PDUs which follow the command FirstBurstLength cannot exceed MaxBurstLengt...

Страница 20: ...PBridge which takes information from the iPBridge and translates it into a form compatible with SNMP If certain conditions arise the agent sends notifications traps to a client Contact your network ad...

Страница 21: ...ting the flash process will make your iPBridge inoperable and you must return it to ATTO Technology for repair Using ATTO ExpressNAV 1 If you have not already open an ExpressNAV session For instructio...

Страница 22: ...host adapter or NIC in host Initiator OS Application Check basic diagnostic tools Check the host event log Check the event log on the host Look for the most recent entries and determine what could be...

Страница 23: ...is enabled 2 Perform a SCSI bus scan on each SCSI port If no devices appear re check SCSI cables and termination If garbage information appears the problem is most likely a bad SCSI cable or terminat...

Страница 24: ...tor the log on screen requests the iPBridge iqn iSCSI qualified name If left blank Adaptec cannot log in Enter iSCSI into this field for auto iqn discovery When changing any setting on the iPBridge th...

Страница 25: ...ys automatically find new targets when plugged in or when forced to rescan Reboot the hosts 3 Check if the vendor has a new driver If so install it Check the applications 1 Verify that the application...

Страница 26: ...he country or other applications slows the system no matter how fast everything else is in the system 1 Verify that the iSCSI storage adapter or NIC is connected to the fastest PCI bus connector suppo...

Страница 27: ...mount of time in seconds before an SRB request will time out ATTO value 300 decimal 0000012c hex Tcp1323Opts This parameter controls RFC 1323 time stamps and window scaling options Time stamps and win...

Страница 28: ...he product faceplate Each port is clickable and takes you to the appropriate page If you have completed configuration operations at any time and have clicked Submit on the page you are viewing go to t...

Страница 29: ...sly A serial port session can use the CLI while Telnet sessions are open Whichever session issues the first set CLI command can continue to issue set commands while the other sessions can only issue g...

Страница 30: ...o 3 meters combined length of both internal and external cable lengths In an UltraSCSI workgroup environment with a 7 drive tower you are limited to 1 5 meters between the host and the tower including...

Страница 31: ...ce cards NICs host bus adapters HBAs and network switches must be Gigabit Ethernet GbE and at least Cat 5e certified Most standard offices use 2 pair wiring which is not compatible GbE requires 4 pair...

Страница 32: ...urns the value of a parameter or setting and is an informational command Responses to get commands are followed by Ready The set form is an action that changes the value of a parameter or configuratio...

Страница 33: ...ils Command Default Example AccessControl disabled for default node enabled for all other nodes set accesscontrol default enabled AccessEntry set accessentry discovery all delete AutoMap automap AutoM...

Страница 34: ...SCSIDomainValidation scsidomainvalidation SCSIInitId 0x07 set scsiinitid 1 12 SCSIPortBusSpeed ultra320 set scsiportbusspeed 1 ultra160 SCSIPortList scsiportlist SCSIPortReset scsiportreset 1 SCSIPor...

Страница 35: ...ed to its own auto named target Automap default target name SaveConfiguration command required AutoMapOnBoot Regulates automatic device detection and mapping AutoMap at startup Default enabled set Aut...

Страница 36: ...s no effect if used during a serial CLI session Exit FirmwareRestart Resets and reinitializes the iPBridge firmware Use the forced option to override any CLI reservations held by other sessions Firmwa...

Страница 37: ...s In and out secrets must be different for each name If discovery is specified the setting applies to CHAP during discovery sessions An in secret authenticates the server to the iPBridge The iPBridge...

Страница 38: ...word and new password confirmation Default Password set Password Ping Sends an ICMP echo request to the specified host If VLAN is enabled the VLAN ID must be provided ping dp1 xxx xxx xxx xxx count si...

Страница 39: ...the test SCSIDomainValidation SCSIInitID Specifies the persistent SCSI initiator ID used by the iPBridge on this SCSI bus All maps coinciding with the user specified ID are destroyed after this comman...

Страница 40: ...not SNMP functions on the iPBridge Default enabled set SNMP enabled disabled get SNMP SNMPDumpMIB Displays the contents of the ATTO iPBridge private SNMP MIB to the current CLI session For further as...

Страница 41: ...ffset from GMT Default EST set TimeZone EST CST MST PST HH MM SaveConfiguration command required get TimeZone Username Specifies the user name for all sessions It is case insensitive 1 to 32 character...

Страница 42: ...tus 001 43 6 1 2 1 2 2 1 1 1 00000032 00000032 0000001e monitor 00000004 002 43 6 1 2 1 2 2 1 1 1 00000032 00000032 00000708 monitor 00000004 003 43 6 1 2 1 2 2 1 1 2 00000032 00000032 0000001e monito...

Страница 43: ...ely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference If this equipment does cause interference to...

Страница 44: ...n will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant The ATTO iPBr...

Страница 45: ...xvi...

Отзывы: