ATTO Technology iPBridge 1550D Скачать руководство пользователя страница 26

21

 

ATTO Technology Inc. iPBridge Installation and Operation Manual

2

Verify that each associated port in the IP SAN 
is configured for 1000Mbs.
IP SAN traffic should be segmented so that it 
does not interfere with the main LAN network 
traffic.For better performance, the IP SAN 
should be on its own set of hardware.

3

Verify that packets are not being dropped along 
the LAN/WAN. Many utilities track packet 
activity and switch statistics.

Check the Ethernet Host Adapter or NIC

Ethernet Storage Adapters generally outperform 
accelerated NICs and un-accelerated NICs by 
offloading most of the processing from the host.
An accelerated NIC provides some offloading, 
but still requires a host OS iSCSI driver, making 
the host spend more CPU cycles.
An un-accelerated NIC does not offload anything 
so the CPU must do much of the processing.
To check the Ethernet host adapter or NIC

1

Verify that the adapter or NIC is sent to auto-
negotiate or forced to 1000 Mb.

2

Set the MTU size to the largest MTU size 
supported in the LAN/WAN. 
9k frame size is the current optimized frame 
size for the iPBridge. Many switch and router 
vendors do not support the larger frame size of 
9k or 16k. Set the maximum transfer size to the 
most efficient size for the intended target(s). 
For many tape drives, 64k is the optimal setting.

Check the applications

Some applications can be configured to change 
transfer sizes. Configure the application for the 
optimal size for the particular SCSI device(s) 
connected to the iPBridge.

Check the host system

The faster the host, the faster your transfer times 
are. The work flow goes only as fast as the slowest 
connection in the host system, so transferring data 
from an IDE drive, 100Mb connection, a DLT 
4000, a high speed RAID volume across the 
country, or other applications, slows the system 
no matter how fast everything else is in the 
system.

1

Verify that the iSCSI storage adapter or NIC is 
connected to the fastest PCI bus connector 
supported by the adapter or NIC.
If the adapter supports PCI-X, place the 
adapter in a PCI-X slot. If one is not available, 
the host might not achieve the optimal 
performance capable from the adapter.
Even placing a PCI-X adapter into a 64 bit 66 
MHz slot loses performance. Some adapters 
adjust clock speed depending on the speed of 
the PCI slot into which they are plugged.

2

The host OS disk and swap disk/partition/file 
should be on a high speed drive such as a SCSI 
drive to minimize the time needed to access the 
host’s virtual memory.
The more memory a system has, the less time 
it spends accessing virtual memory (hard drive 
space).

Check the Operating System

If possible, eliminate swap space and virtual 
drives which require large amounts of system 
memory. However, the OS might not allow the 
elimination of swap space. An OS set to run many 
kinds of different servers spends much of its CPU 
cycle on other operations, thus slowing down 
performance.

Use the ATTO iSCSI performance 
configuration tool (Windows only)

The ATTO iSCSI performance configuration tool 
changes the Windows registry parameters for 
Microsoft iSCSI Initiator and TCP/IP to enhance 
overall data throughput.

1

From the CD which came with your iPBridge, 
copy the 

Perftune.exe

 file to your hard drive.

2

Execute the program. 

3

Click on 

Use ATTO Performance Settings

Settings take effect on the next system reboot.

The following settings are affected:

FirstBurstLength

The maximum amount, in bytes, of unsolicited data an 
iSCSI initiator may send to the target during the 
execution of a single SCSI command including the 
immediate data and the sequence of unsolicited Data-Out 
PDUs which follow the command. 

FirstBurstLength

 

cannot exceed 

MaxBurstLength

 

ATTO value: 1048576 decimal 00100000 hex

Содержание iPBridge 1550D

Страница 1: ...iPBridge 1550D Installation and Operation Manual...

Страница 2: ...chnical support Monday Friday 8am 8pm EST techsupp attotech com 2007 ATTO Technology Inc All rights reserved All brand or product names are trademarks of their respective holders No part of this manua...

Страница 3: ...Setting up Internet Explorer Beginning initial configuration 3 Configure the iPBridge 7 Preliminary steps ExpressWizard 3 1 Target management 9 Target names Default target node Automatically configure...

Страница 4: ...formance issues Check SCSI devices Check the iPBridge SCSI port Check the iPBridge Ethernet port Check the LAN WAN Check the Ethernet Host Adapter or NIC Check the applications Check the host system C...

Страница 5: ......

Страница 6: ...ng your existing storage capacity without sacrificing performance The ATTO iPBridge 1550 is ideally suited to the SME or for corporate IT departments seeking to expand storage requirements with minima...

Страница 7: ...2 Exhibit 1 0 1 Possible storage solutions using the iPBridge...

Страница 8: ...ended SCSI Ethernet port The 10 100 1000 GbE RJ 45 Ethernet port uses the Intel 8254x family gigabit Ethernet chipset to support iSCSI data transfer and inbound management GbE cables must be at least...

Страница 9: ...4 Exhibit 1 1 1 iPBridge 1550D back panel...

Страница 10: ...r the iPBridge Ready LED to light indicating the bridge has completed its power on self test sequence 8 Windows users continue to Installing Windows drivers Mac users continue to Discovering the IP ad...

Страница 11: ...3 Click OK to close the iSCSI Initiator utility You should now have storage you can manage through Windows Disk Management Continue to Beginning initial configuration Installing iSCSI Initiator for Ma...

Страница 12: ...one of three ways Review the settings keeping the automatic settings created when you powered up your iPBridge and do nothing now Use the ExpressWizard accessed from the side menu to initially set up...

Страница 13: ...ed Change any elements as needed 12 Click Next 13 The configuration for the iPBridge based on your input in the previous screens appears If the information is correct click Commit 14 The ExpressWizard...

Страница 14: ...target with Access Control ACL disabled and CHAP authentication disabled The default target node cannot be deleted Use the ExpressNAV interface to map devices automatically or manually Refer to Openi...

Страница 15: ...the ExpressNAV main menu click on the Automatic Target Management menu item on the left side of the screen 3 Click on the Map each device to its own target button A target name suffix is attached to t...

Страница 16: ...11 ATTO Technology Inc iPBridge Installation and Operation Manual Exhibit 3 1 1 Target node configurations...

Страница 17: ...dge will delegate its access control authorization to an iSNS server Default is disabled Note iSNS Login Control cannot be used with Access Control found on the iSCSI Target Management page iSNSServer...

Страница 18: ...ndicated 4 Enter appropriate information into the New Admin Password Confirm New Admin Password or New Read Only Password and Confirm New Read Only Password text boxes 5 Click Submit 6 Go to the Resta...

Страница 19: ...he target during the execution of a single SCSI command including the immediate data and the sequence of unsolicited Data Out PDUs which follow the command FirstBurstLength cannot exceed MaxBurstLengt...

Страница 20: ...PBridge which takes information from the iPBridge and translates it into a form compatible with SNMP If certain conditions arise the agent sends notifications traps to a client Contact your network ad...

Страница 21: ...ting the flash process will make your iPBridge inoperable and you must return it to ATTO Technology for repair Using ATTO ExpressNAV 1 If you have not already open an ExpressNAV session For instructio...

Страница 22: ...host adapter or NIC in host Initiator OS Application Check basic diagnostic tools Check the host event log Check the event log on the host Look for the most recent entries and determine what could be...

Страница 23: ...is enabled 2 Perform a SCSI bus scan on each SCSI port If no devices appear re check SCSI cables and termination If garbage information appears the problem is most likely a bad SCSI cable or terminat...

Страница 24: ...tor the log on screen requests the iPBridge iqn iSCSI qualified name If left blank Adaptec cannot log in Enter iSCSI into this field for auto iqn discovery When changing any setting on the iPBridge th...

Страница 25: ...ys automatically find new targets when plugged in or when forced to rescan Reboot the hosts 3 Check if the vendor has a new driver If so install it Check the applications 1 Verify that the application...

Страница 26: ...he country or other applications slows the system no matter how fast everything else is in the system 1 Verify that the iSCSI storage adapter or NIC is connected to the fastest PCI bus connector suppo...

Страница 27: ...mount of time in seconds before an SRB request will time out ATTO value 300 decimal 0000012c hex Tcp1323Opts This parameter controls RFC 1323 time stamps and window scaling options Time stamps and win...

Страница 28: ...he product faceplate Each port is clickable and takes you to the appropriate page If you have completed configuration operations at any time and have clicked Submit on the page you are viewing go to t...

Страница 29: ...sly A serial port session can use the CLI while Telnet sessions are open Whichever session issues the first set CLI command can continue to issue set commands while the other sessions can only issue g...

Страница 30: ...o 3 meters combined length of both internal and external cable lengths In an UltraSCSI workgroup environment with a 7 drive tower you are limited to 1 5 meters between the host and the tower including...

Страница 31: ...ce cards NICs host bus adapters HBAs and network switches must be Gigabit Ethernet GbE and at least Cat 5e certified Most standard offices use 2 pair wiring which is not compatible GbE requires 4 pair...

Страница 32: ...urns the value of a parameter or setting and is an informational command Responses to get commands are followed by Ready The set form is an action that changes the value of a parameter or configuratio...

Страница 33: ...ils Command Default Example AccessControl disabled for default node enabled for all other nodes set accesscontrol default enabled AccessEntry set accessentry discovery all delete AutoMap automap AutoM...

Страница 34: ...SCSIDomainValidation scsidomainvalidation SCSIInitId 0x07 set scsiinitid 1 12 SCSIPortBusSpeed ultra320 set scsiportbusspeed 1 ultra160 SCSIPortList scsiportlist SCSIPortReset scsiportreset 1 SCSIPor...

Страница 35: ...ed to its own auto named target Automap default target name SaveConfiguration command required AutoMapOnBoot Regulates automatic device detection and mapping AutoMap at startup Default enabled set Aut...

Страница 36: ...s no effect if used during a serial CLI session Exit FirmwareRestart Resets and reinitializes the iPBridge firmware Use the forced option to override any CLI reservations held by other sessions Firmwa...

Страница 37: ...s In and out secrets must be different for each name If discovery is specified the setting applies to CHAP during discovery sessions An in secret authenticates the server to the iPBridge The iPBridge...

Страница 38: ...word and new password confirmation Default Password set Password Ping Sends an ICMP echo request to the specified host If VLAN is enabled the VLAN ID must be provided ping dp1 xxx xxx xxx xxx count si...

Страница 39: ...the test SCSIDomainValidation SCSIInitID Specifies the persistent SCSI initiator ID used by the iPBridge on this SCSI bus All maps coinciding with the user specified ID are destroyed after this comman...

Страница 40: ...not SNMP functions on the iPBridge Default enabled set SNMP enabled disabled get SNMP SNMPDumpMIB Displays the contents of the ATTO iPBridge private SNMP MIB to the current CLI session For further as...

Страница 41: ...ffset from GMT Default EST set TimeZone EST CST MST PST HH MM SaveConfiguration command required get TimeZone Username Specifies the user name for all sessions It is case insensitive 1 to 32 character...

Страница 42: ...tus 001 43 6 1 2 1 2 2 1 1 1 00000032 00000032 0000001e monitor 00000004 002 43 6 1 2 1 2 2 1 1 1 00000032 00000032 00000708 monitor 00000004 003 43 6 1 2 1 2 2 1 1 2 00000032 00000032 0000001e monito...

Страница 43: ...ely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference If this equipment does cause interference to...

Страница 44: ...n will only be valid when this product is used in conjunction with other CE approved devices and when the entire system is tested to the applicable CE standards and found to be compliant The ATTO iPBr...

Страница 45: ...xvi...

Отзывы: