IMPORTANT - Warning Note!
Properly installed, operated and maintained this appliance will not emit fumes into the
dwelling. Occasional fumes from de-ashing and re-fuelling may occur. However, persis-
tent fume emission is potentially dangerous and must not be tolerated. If fume emis-
sion does persist, the following immediate actions should be taken:
1. Open doors and windows to ventilate room.
2. Let the fire out or eject and safely dispose of fuel from the appliance.
3. Check for flue or chimney blockage, and clean if required.
4. Do not attempt to relight the fire until the cause of the fume emission has been
identified and corrected. If necessary seek expert advice.
IMPORTANT - Warning Note!
Do not use an aerosol spray on or near the stove when it is alight.
IMPORTANT - Safety advice!
When using the stove in situations where children, aged and/or infirm persons are pres-
ent a fireguard must be used to prevent accidental contact with the stove. The fire-
guard should be manufactured in accordance with BS 8423:2002 (Replaces BS 6539).
Lighting and fuelling
NOTE!
If airsystem is connected, the valve must be open.
TIPS before firing up:
Open a door or window close to the wood burning. If there is a “storm” in the stove
coming from the chimney, it is advisable to place a screwed-up piece of newspaper be-
tween the upper baffle plate and the chimney, set the paper on fire, and wait until you
hear a “rumbling” noise in the chimney. This means that there definitely is a draught
in the chimney and you avoid smoke in the room.
”Top-Down” lighting
For reference see photos (back of manual).
• Open the door fully until it is locked in the open position.
• Start by placing approx. 1kg of wood - 2 pcs. of wood - (photo 1) in the bottom of
the combustion chamber. Place approx. 1.2 kilograms of dry firewood (photo 2),
split into kindling sticks, and a couple of alcohol briquettes or similar.
• Light the fire (photo 3+4).
• Set the air damper to fully open pos. 3 (approx 15 min.), then at pos. 2.
• Close the door, leaving the door ajar approx 1-2 cm.