background image

4

5

1.

 After open packing machine, please check carefully whether specifications and test report or 

      carry with specifications conform with the order, the contract if required. If not, please 
            c o n t a c t   w i t h   o u r   s a l e s   d e p a r t m e n t ,   t h e   w a y   t o   p r o p e r l y   h a n d l e .

This company produces the power used for the contemporary world advanced technical 
achievement, after careful thermal design and structure optimization and become a unique 
multiterminal function device. Due to the function of the device, series and varieties, its function
is maths and physical properties and each different, so in the installation and use of many 

INSTALLATION AND USE AND MAINTENANCE 
INSTRUCTIONS

(5) 
(6) 

3. Constant voltage/current characteristics

   

This series of the power supply characteristics of constant is called the voltage/current, it can 
automatic conversion model with constant voltage change of load in with constant current 
condition of constant voltage between successive changes, with constant current intersection 
between normal moveout called. For example, if the power load working in constant pressure 
mode, stable output voltage. As the load decreases, output voltage will remain stable, until it 
reaches pre-set limit flow value. To be worth, maintain stable output current, voltage output as 
load increases proportional to further reduce, constant voltage and current of the conversion from 
the front panel LED indicator. Similar to the constant current constant voltage from the automatic 
conversion is reduced with the load. Constant voltage, current CV indicator when CC indicator.

4. Operating methods

     

Will the power switch in "OFF" position.

     

Ensure input voltage correct.

     

When the power is connected.

     

Will the power switch ON the "ON" position.

     

Set the output voltage values to work and Set the output required load current value, Please 

    adjust "VOLTAGE" and "CURRENT" knob.

     

Connects the load to Positive "+" terminals  and Negative "-" terminals.

     

When used in ripple and noise higher requirements, output "+" and "-" terminals must have a 

    reliable connection with GND terminals, this can reduce output ripple and noise.

Current (overload protection) Settings, do not change after the current knob.
Take off a short line, can enter working condition.

Maintenance

Fuse replaced

If the fuse burning, voltage or current indicator goes out, the power to stop working, 
besides problems generally fuse box, do not open to identify and correct fuse burned, 
and then use the same value of the fuse.

2.

 As the first step before use, must be the metal shell reliable power grounding to ensure the 

      safe, but do not mistake will meet in neutral Shell.

3.

 In the installation, please complete electricity run again before each examination and

      proofreading terminals, confirm the input and output, AC and DC, positive and negative, 
      voltage and current, no doubt, eliminate such right after the fault phenomena.

4.

 

Power does not allow for a long time in full load status, please send full load rate of 

      regulated dc power supply control in 60%, within the switch power supply load rate control
      in 80% within, otherwise will likely cause of the failure of early human. According to the 
      actual working order should be set aside by current surplus.

5.

 

To achieve full scattered heat effect, Power should be installed on the air convection 

      condition good position. General power work should have a good ventilation. In addition, in 
      the upper crust  power does not allow other objects placed.

6.

 This power is applicable to resistance of load, if need to let in Capacitive load Inductive load, 

      should give priority to the load in advance in order to illustrate the contract, if by oversight 
      will load property shall be timely and correctly, contact the company sales, to seek the offset 
      schemes Properly.

7.

 For high voltage power supply, it is necessary to safety. Use process and the blackout after 

      10 minutes, do not touch pressure apparatus.

8.

 

If power failure, should take the most efficient way to taste deliery to the fault, the company 

      will depending on the situation is different, or repair or replacement. Users must not without 
      disassembly of power, otherwise will force to our company for analysis of failure caused 
      difficulties and make judgment work both suffered a new loss.

specialized in the note, the explanation: