Compensation curve and curve shifting
By holding the ,,reset" button (See6 - Pic.1 KST, KT) or the ,,mode" button(See 10 - Pic.2 KZT ) for 5
seconds opens the menu of the „Controlled temperature“, the flickering „CU“ is dipslayed. Adjust the
required curve by the DHW buttons (marked as 1 and 2, pics. 1 and 2) from 1 to 10, adequately to the
characteristics. Regulation of the controlled temperature is cancelled by adjusting curve to 0.
Compensation curve
Option of the parallel curve shift, the flickering „Of“is displayed by pressing the heating buttons (See 3
and 4 - Pics.1 and 2). Set the parallel curve shift adequately to the characteristic by the DHW buttons
(See 1 and 2 - Pics. 1 and 2).
Compensation curves
Parallel curve shift
Repeated pressing of the button „Reset“ (See 6 - Pic.1 KST, KT ) and „Mode“(See 10- Pic.2 KZT ) for
5 seconds enables to exit mode of the parallel curve regulation. If the environment temperature is lower
than required temperature, it recommended to set more abrupt curve and vice-versa. Decrease or increase
for 1 unit and check the result in the room.
Regulation with time remote control
If the time remote control (additional equipment) is connected to the boiler, the above mentioned
operations are controlled per boiler display and the „FH“ text appears.
Regulation of the heating temperature
Regulation can be performed via menu of the time remote control, as well as via the boiler´s control
panel.
Regulation of the DHW temperature (with external DHW tank installed)
Regulation can be performed via menu of the time remote control, as well as via the boiler´s control
panel.
Switching Summer/Winter
The Summer mode has priority over the eventual requirement for heating from the remote control.
Selection Eco/Comfort
If the DHW warming is turned off by the remote control, boiler is switched into the Economy mode.
Therefore is the button (See 7 - Pics.1 and 2) on the boiler control panel out of order. If the DHW
warming is turned on by the remote control, the boiler is switched to the Comfort mode. Therefore it is
possible to set one of the two modes through the button (See 7 - Pics. 1 and 2).
Controlled temperature (
OPENTHERM )
The OPENTHERM communication is built into the electronic control board of the boiler. All the boiler
functions are controlled through programmable Opentherm regulator (Ordering code: OT36A).
Programmable regulator and the room thermostat are not included to the boiler accessories.