Opera ting Ma nua l a nd Inspection Book
SMART LIFT 2.30 SL, 2.35 SL, 2.40 SL / HYMAX S 3000, 3500, 4000
20110015 OPI
55
Version 1.0
Selection the Liebig anchor without floor cover (screed, tiles)
(valid 2.30 SL, 2.35 SL, 2.40 SL)
Hole diameter 22 mm in the baseplate
Liebig anchor
Anchor type
BM12-20/80/40
Hole depth
a
100
Min. anchoring depth
b
80
Concrete thickness
c
Min.160 (*)
Hole diameter
d
20
Component thickness
e
0-40
Concrete quality
Min.C20/25 normal reinforcement (1)
Number of anchors
Depending on the lift type
Torque of the anchors
70 Nm
(*) Min. concrete thickness when using the above-mentioned anchor, otherwise follow the
details in the foundation plans.
Similar value anchors and other known brands of anchor manufacturers can be used when
considering the conditions.
(
1
) Declaration: normal reinforcement
A normal reinforcement is present if the axis separation in the area of the anchor with a
rod diameter of
≥ 10 mm is 150 mm, or for a rod diameter of ≤ 10 mm is 100 mm.