23
Copyright © 2009 ATSG
AUTOMATIC TRANSMISSION SERVICE GROUP
Technical Service Information
Electrical Conductor
Plate Connector
(Face View)
1
6
10
13
11
7
3
2
No. 5 not used
12
8
4
9
12
13 14 15
16
17
33
34 35 36
37
38
L
H
TCM "C2"
Connector
1-2/4-5 Shift Solenoid
3-4 Shift Solenoid
2-3 Shift Solenoid
TCC (PWM) Solenoid
Modulation Pressure Control (MPC) Solenoid
Shift Pressure Control (SPC) Solenoid
TFT Sensor
SOLENOID OHMS TEST AT THE TCM OR CASE CONNECTOR
TCM
Term No's.
Electrical Conductor
Plate Term No's.
Resistance
Specification
Component
14 & 38
15 & 38
16 & 38
17 & 38
36 & 38
37 & 38
13 & 34
6 & 13
6 & 9
6 & 8
6 & 11
6 & 2
6 & 10
4 & 7
2.5 - 6.5 Ohms
2.5 - 6.5 Ohms
2.5 - 6.5 Ohms
2.0 - 4.0 Ohms
2.5 - 6.5 Ohms
2.5 - 6.5 Ohms
See Chart - Figure 18
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Function
N3 Input Speed Sensor Signal
Modulation Pressure Control Solenoid Ground Control
N2 Input Speed Sensor Signal
TFT Sensor and P/N Switch Signal
Not Used
Battery Supply Voltage For All Solenoids
Sensor 5V Supply Voltage
2-3 Shift Solenoid Ground Control
3-4 Shift Solenoid Ground Control
Shift Pressure Control Solenoid Ground Control
TCC Solenoid Ground Control
Sensor Ground
1-2/4-5 Shift Solenoid Ground Control
ELECTRICAL CONDUCTOR PLATE CONNECTOR TERMINAL IDENTIFICATION
Figure 23