Installation, Operation and 

Maintenance Manual

CAUTION: Read and Follow all safety rules and 
operating instructions before first use of product.

M

ODEL

:

 

DWS- 25

DRINKING WATER STERILIZER

Ultraviolet Disinfection Systems

Содержание DWS-25

Страница 1: ...nstallation Operation and Maintenance Manual CAUTION Read and Follow all safety rules and operating instructions before first use of product MODEL DWS 25 DRINKING WATER STERILIZER Ultraviolet Disinfec...

Страница 2: ...2...

Страница 3: ...Function Description 5 Installation Diagram 6 Sanitation Procedure 7 8 Maintenance 9 Wiring Diagrams 10 Parts Breakdown 11 Troubleshooting 12 Sterile Water Sample Procedures 13 Specifications 14 Warr...

Страница 4: ...an unsafe condition 7 Intended for indoor use Do not install this disinfection system where it will be exposed to the weather Do not store this disinfection system where it will be exposed to temperat...

Страница 5: ...rated capacity of the unit The DWS series has an unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surrounded by a stainless steel pressure chamber The chamber is...

Страница 6: ...support Use anchors with screws for sufficient support not included A lock nut secures the mounting bracket to the U V chamber If your piping system is subject to impulse pressure resulting in a water...

Страница 7: ...the well and storage tank should be treated with a strong chlorine solution to destroy disease organisms All pipelines and fixtures in the distribution system should be rinsed and flushed with chlori...

Страница 8: ...the water if necessary Plumbing Line Sanitation Only When installing an ultraviolet disinfection system a pre filter with sump may serve as a source to sanitize the water lines only For whole system d...

Страница 9: ...ng on any threaded part of the nipple Hand tighten each compression nut to form a compressionsealaroundthequartzsleeve Avoidovertightening the nuts which may cause a fracture on the end of the quartz...

Страница 10: ...10 Wiring Diagram DWS 2020 www aquat com...

Страница 11: ...11 Parts Breakdown DWS 2020 www aquat com...

Страница 12: ...disconnected Check replace or outlet defective Defective U V lamp Replace Defective lamp ballast Check output voltage Replace ballast Loose open circuit wire Trace out and repair Leak at quartz nippl...

Страница 13: ...erile bottle or sterile container being used Holding the cap in a down position the operator should then hold his breath while taking the sample so as to avoid oral contamination of the sample The ope...

Страница 14: ...14 Specifications DWS 2020 www aquat com...

Страница 15: ...15 Notes DWS 2020 www aquat com...

Страница 16: ...16 Warranty DWS 2020 www aquat com...