Maintenance

sleeve).  Replace O-Ring [ATS8-544(2)] every time a quartz 

sleeve is cleaned or replaced. We reccommend replacing the 

quartz sleeve once a year.

U.V. LAMPS:

INSTALLATION OF THE ULTRAVIOLET LAMPS:

**DO NOT PUT POWER ON AT THIS TIME!**
CAUTION: Never operate or look directly at  U.V. 

lamp outside the disinfection chamber.

Make sure unit is unplugged when installing or servicing 

ultraviolet lamp.  Remove any paper tabs on the U.V. lamp 

and avoid allowing fingerprints and other debris to deposit.  

Carefully place the lamp inside the quartz sleeve leaving 

enough space to connect the socket connector to the lamp 

pins.  Then gently slide the brass dust cap over the end nut, 

securing the lamp and protecting it from dust.

ULTRAVIOLET LAMP MAINTENANCE 

REQUIREMENTS:
The U.V. lamp is rated for 9,000 hours of continuous use.  

After this period of time, the U.V. lamp has undergone a 

photochemical change.  While the lamp will not normally be 

burned out, the lamp quartz may no longer emit the 254-nm 

shortwave U.V. to effectively kill bacteria.  Failure to replace 

the U.V. lamps every 9,000 hours may cause bacteriological 

breakthrough.  Should the use of the disinfection unit be 

intermittent, in no case should the U.V. lamp be used for 

more than 24 months regardless of the number of hours 

of operation due to normal shelf life degradation of the 

U.V. bulb.  Changing the quartz sleeve should be done

at the same time U.V. lamp replacement is scheduled.
It is recommended that your water supply be tested 

periodically (yearly) through your local health department or 

approved certified laboratory.

ELECTRICAL:
The DWS/DWSW series are furnished with 6’ line cord that 

will plug into a 110V outlet.  Electrical receptacles must be 

properly grounded for safe operation.  Improper grounding 

will void any warranty.
When possible use a separate breaker to minimize voltage 

fluctuations  and  avoid  accidental  shut  off.    After  unit  is 

installed and water is turned on, plug the unit into 110V wall 

receptacle.  View lamp operation through safety Sight Port 

lens.  
NOTE: Avoid exposing your eyes to U.V. light.

QUARTZ SLEEVE:
Installation of the Quartz Sleeve:
Always handle quartz sleeves carefully to prevent breaking 

or chipping. The quartz sleeves are to be clean and free of 

fingerprints before installing.  
Remove the compression nut. Install the quartz 

sleeve through the stainless steel threaded nipple 

allowing an equal amount to extend beyond each 

nipple.    Install  the  O-Ring  down  the  top  of  the  

nipple.  Avoid riding the  O-Ring on any threaded part of 

the nipple.  Hand-tighten each compression nut to form a 

compression seal around the quartz sleeve. Avoid overtightening 

the nuts, which may cause a fracture on the end of the quartz 

sleeve.  Under normal operation conditions, hand-tightening 

will provide a 100 psi seal.  Do not use any devices to tighten end 

nuts. Repeat this procedure at the opposite end of the chamber.
After you have tightened the compression nut and 

all other plumbing connections, open the outlet 

valve. Slowly open the inlet valve and flush out 

all remaining air. Then close the outlet valve and 

 

slowly open the inlet valve fully.  Check the unit for leaks.  

If  you  find  a  leak  at  the  compression  nut,  tighten  the  nut 

further.  If the leak continues, drain the unit and inspect 

the quartz O-Ring and  quartz sleeve for proper seal.  Once 

you  complete  checking  the  unit,  reassemble  O-Ring  and 
tighten gland nut.  Repressurize the unit and check again.

REQUIREMENTS FOR CLEANING THE QUARTZ 

SLEEVE:
As water passes through the U.V., minerals, debris and other 

matter in the water may deposit onto the quartz sleeve.  After 

sufficient film has formed on the quartz sleeve, the ability of 

the ultraviolet germicidal rays to pass though the quartz sleeve 

and into the water may be impaired.  Therefore, it is necessary 

to determine a cleaning schedule for the quartz sleeve.  The 

frequency will depend on the specific type of water conditions.  

If the water has been processed through deionization, reverse 

osmosis, or is distilled, cleaning may be required only once per 

year.  If untreated water is used, the cleaning frequency will 

vary.  A minimum of once yearly is standard recommendation 

for cleaning and lamp replacement.  Contact your local dealer 

for scheduling this service.  Your specific situation will vary the 

frequency time according to the water quality of the home or 

facility application. 
QUARTZ SLEEVE CLEANING PROCEDURES:
To  clean  the  quartz  sleeve,  turn  off  the  water  flow  to  the 

disinfection unit, turn power off, and at a separate faucet or 

valve relieve the water pressure from the UV. Then disconnect 

the electrical service to the lamp pins.  Carefully remove the 

U.V. lamp.  Loosen the end nut with O-Ring and remove the

quartz sleeve.  The quartz sleeve may then be washed with a

mild soap and hot water solution and rinsed clean with hot

water.  Should this be insufficient to clean the quartz sleeve,

a mild acid may be used (i.e. vinegar).  Be certain to follow

all recommended safety and handling procedures on the acid

container.  It is important to handle the quartz sleeve with care

to prevent breakage.  Make certain that all finger prints are

wiped clean before reinstalling (see installation of the quartz

DWS © 20

20

 • www.aquat.com        

Содержание DWS-25

Страница 1: ...nstallation Operation and Maintenance Manual CAUTION Read and Follow all safety rules and operating instructions before first use of product MODEL DWS 25 DRINKING WATER STERILIZER Ultraviolet Disinfec...

Страница 2: ...2...

Страница 3: ...Function Description 5 Installation Diagram 6 Sanitation Procedure 7 8 Maintenance 9 Wiring Diagrams 10 Parts Breakdown 11 Troubleshooting 12 Sterile Water Sample Procedures 13 Specifications 14 Warr...

Страница 4: ...an unsafe condition 7 Intended for indoor use Do not install this disinfection system where it will be exposed to the weather Do not store this disinfection system where it will be exposed to temperat...

Страница 5: ...rated capacity of the unit The DWS series has an unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surrounded by a stainless steel pressure chamber The chamber is...

Страница 6: ...support Use anchors with screws for sufficient support not included A lock nut secures the mounting bracket to the U V chamber If your piping system is subject to impulse pressure resulting in a water...

Страница 7: ...the well and storage tank should be treated with a strong chlorine solution to destroy disease organisms All pipelines and fixtures in the distribution system should be rinsed and flushed with chlori...

Страница 8: ...the water if necessary Plumbing Line Sanitation Only When installing an ultraviolet disinfection system a pre filter with sump may serve as a source to sanitize the water lines only For whole system d...

Страница 9: ...ng on any threaded part of the nipple Hand tighten each compression nut to form a compressionsealaroundthequartzsleeve Avoidovertightening the nuts which may cause a fracture on the end of the quartz...

Страница 10: ...10 Wiring Diagram DWS 2020 www aquat com...

Страница 11: ...11 Parts Breakdown DWS 2020 www aquat com...

Страница 12: ...disconnected Check replace or outlet defective Defective U V lamp Replace Defective lamp ballast Check output voltage Replace ballast Loose open circuit wire Trace out and repair Leak at quartz nippl...

Страница 13: ...erile bottle or sterile container being used Holding the cap in a down position the operator should then hold his breath while taking the sample so as to avoid oral contamination of the sample The ope...

Страница 14: ...14 Specifications DWS 2020 www aquat com...

Страница 15: ...15 Notes DWS 2020 www aquat com...

Страница 16: ...16 Warranty DWS 2020 www aquat com...

Отзывы: