15
TROUBLESHOOTING GUIDE
PROBLEM
CAUSE
CORRECTION
U.V. lamp will not light
Check input voltage if below
Install a voltage regulator
or
above
120
volts
Line
cord
disconnected
Check,
replace
or
outlet
defective
Defective
U.V.
lamp
Replace
Defective
lamp
ballast
Check
output
voltage
Replace
ballast
Loose
open-circuit
wire
Trace
out
and
repair
Leak at quartz nipple
Defective or cracked O-Ring
Replace O-Ring
O-Ring
not
seated
properly
Replace
O-Ring