Operating / P-Level
51
January 2006 / Rev. 1.0
SET CLOCK
The internal clock of the machine can be set in this
menu. Highlight the figure to be changed and press
the center lit button to start changing the value.
Date format:
DD-MM-YYYY
Confirm setting with "Cash Out" button.
HOPPER OUT (HOPPER 1)
By means of the HOPPER OUT test routine the hopper
coin switch adjustment can be tested.
• Run HOPPER OUT (5 COINS) test by pressing
the middle lit button for 4 sec.
• Make sure exact 5 coins were paid out.
• Repeat the test for additional security.
• Run HOPPER SWITCH TEST by pressing the left
lit button for 4 sec. Hopper will perform a coin
out until it is empty or Reset Button is pressed.
• The switching period values (in msec) are dis-
played. If any of the values is below 12 msec the
Hopper count switch has to be re-adjusted. See
manual Peripherals/Hopper for details.
HOPPER OUT (HOPPER 2)
Applicable only if a second (residual credits) Hopper is
installed.
SERVICE MENU