5
/
22
III.
Installation
Installation Check List
1, Is the Ice Machine level?
2, Have all of the electrical and water connections been made?
3, Has the supply voltage been tested and checked against the rating on the
nameplate?
4, Is there proper clearance around the ice machine for air circulation?
5, Is the ice machine grounded and polarity correct?
6, Has the ice machine been installed where ambient temperatures will remain
in the range of 35° - 110°F (1.6° - 43.3°C)?
7, Is there a separate drain for the potable water, bin and water-cooled
condenser?
8, Are all electrical leads free from contact with refrigeration lines and moving
equipment?
9, Has the owner/operator been instructed regarding maintenance and the use
of the specified Cleaner and Sanitizer?
10, Has the owner/operator completed the warranty registration card?
11, Has the ice machine and bin been sanitized?
12, Is the ice thickness control set correctly? (Refer to Operational Checks to
check/set the correct ice bridge thickness).
1.
Power supply
•
Warning
*
All wiring must comply with national and local laws and regulations
*
The ice maker must be earthed properly
All electrical operations involved must comply with the following:
1) the ice maker must be grounded;
2) each ice maker must be individually fitted with fuses or breaker;
3) a qualified electrician must be needed with the wires;
4) the ice maker starts with the maximum load and the maximum allowable
voltage fluctuates by +/- 10%;
5) check that the socket is securely fastened before starting.
Match fuse or breaker and machine circuit current
Model
YR140-AP-161
YR280-AP-161 YR450-AP-161 YR800-AP-261
V/P/F
110V/1/60Hz
110V/1/60Hz
110V/1/60Hz
230V/1/60Hz
Fuse/breaker
10A
16A
20A
25A
Min circuit
3.5A
6.8A
9.7A
9.8A