background image

2

1.INTRODUCTION

Please read instructions before using this appliance.

IMPORTANT SAFETY INSTRUCTION

▲ To reduce the risk of fire, electric shock, or injury to persons when using your product, basic safety
precautions should be followed, including the following.
▲ This appliance must be properly installed and located in accordance with the Installation Instruction
before it is used.
▲ Before the appliance is plugged in, ensure that the rated voltage corresponds to the voltage of the
electrical system in your home. The power plug should have its own independent socket. Using adapters
may cause overheating or burning.
▲ This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved.
▲ Children shall not play with the appliance.
▲ Cleaning and user maintenance shall not be made by children without supervision.
▲ If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
▲ Connect to properly grounded outlets only. Avoid the use of extension cords. Do not run cord under
carpeting, runners or the like. Arrange cord away from traffic area and where it will not create a tripping
hazard.
▲ Always unplug appliance when not in use and before cleaning, adjusting or maintaining this machine.
To disconnect appliance, turn switch off and remove plug from power source.
▲ Do not disconnect by pulling on the cord. Always disconnect by grasping and pulling on the plug top.
▲ Do not pull out the cord or touch the power plug with wet hands. Clean water or dust from the power
plug and insert it with the ends of the pins securely connected.
▲ Do not use outdoors.
▲ Do not splash water on the appliance. It may cause a malfunction or electric shock.
▲ Do not disassemble, repair or alter the appliance. It may cause fire or abnormal operations, which
may lead to injury.
▲ After your fridge-freezer is in operation, do not touch the cold surfaces in the freezer compartment,
particularly when hands are damp or wet. Skin may adhere to these extremely cold surfaces.
▲ Never place glass products in the freezer because they may be broken when their inner contents are
frozen.
▲ The refrigerant and insulation blowing gas used in the appliance require special disposal procedures.
When disposal, please consult with service agent or a similarly qualified person.
▲ Do not store explosive substances such as aerosol cans with a flammable propellant in this
appliance.
▲ If you need the electronic version instruction manual, please ask the manufacturer or its service
agent .
▲ Max. Load of shelf is 88 lbs.

Содержание EBF-03

Страница 1: ...Original instruction INSTRUCTION MANUAL Blast Chiller Cabinets Please read the user s manual before you use this product ...

Страница 2: ......

Страница 3: ...ctly accessing the parameters by selecting the category 10 6 7 Alarms with manual reset 10 6 8 HACCP function 10 6 9 Procedure for setting the default parameter values 11 7 MANITENANCE 11 7 1 PERIODIC CLEANING 11 7 2 CLEANING OF CONDENSER 11 7 3 PERIOD OF INACTIVITY OF CABINET 11 8 TROUBLE SHOOTING AND REMEDIES 12 8 1 If the cabinet does not operate make sure that 12 8 2 If the required temperatur...

Страница 4: ...der carpeting runners or the like Arrange cord away from traffic area and where it will not create a tripping hazard Always unplug appliance when not in use and before cleaning adjusting or maintaining this machine To disconnect appliance turn switch off and remove plug from power source Do not disconnect by pulling on the cord Always disconnect by grasping and pulling on the plug top Do not pull ...

Страница 5: ...uidelines indicated herein misuse of the refrigerator power supply defects improper or inadequate maintenance unauthorised modification or tampering use of non original spare parts partial or total failure to comply with the instructions All electrical equipment can be hazardous to health Current standards and legal requirements must be complied with during the installation and use of any equipmen...

Страница 6: ...abinet by application of pressure to the surface if the device has been positioned horizontally integral condensing unit wait two hours before activating it Packing and protective film should be disposed off as indicated by the local authorities The equipment must not be installed within explosive amblence In the open air or exposed to rain the correct siting is distant from direct sources radiato...

Страница 7: ...electrical safety feature have this introduced by a qualified person by means of a omnipolar switch as indicated in the safety regulations with a means of a omnipolar switch as indicated in the safety regulations with a minimum clearance of the contacts of 3 mm where the cabinet has to be installed at some distance from the electrical source ensure that the conforms to the local regulations Cabine...

Страница 8: ...level of the equipment fitted with integral hermetic condensing unit does not exceed 70 dB it is therefore not necessary to provide sound insulation Under normal conditions the equipment does not generate vibrations which affect surroundings 5 2 POSSIBLE USAGES Do not utilise the equipment to store medical supplies the optimum operational ambient temperatures are between 10 32 ...

Страница 9: ...7 6 USAGE 6 1 ACTION These devices are activated by one switches and an electronic control panel 6 2 Meaning of the button ...

Страница 10: ...8 6 3 Selecting the BLAST CHILLING cycle ...

Страница 11: ...word set is 22 the display will scroll the list of type C parameters CONFIGURATION otherwise the list of type F parameters FREQUENT Set the desired value 5 Press START The display will show the parameter name This is the current value of the parameter 6 Press UP or DOWN The value on the display will increase or decrease Set the desire value 7 Press START The display will show the parameter name ag...

Страница 12: ...nthe table below according to the list on the display with the corresponding name and icon To directly access the list of parameters grouped bycategory press the PRG button for at least 1 second and to modify the parameter press DOWN START UP Category Paraneters Message Icon Probe parameters pro Control parameters r Ctl Compressor parameters c CMP Defrost parameters d dEF Alarm parameters A ALM Fa...

Страница 13: ...ch the instrument off 2 switch the instrument back on holding the PRG button until the value bn0 is shown on the display 3 select the set of default parameters between 0 and Hdn using the DOWN and UP buttons 4 press the START button until the message Std is shown on the display 7 MANITENANCE 7 1 PERIODIC CLEANING For hygienic reasons and improved performance clean at least once a month the interna...

Страница 14: ...roper air circulation 8 3 If the cabinet leaks water make that The collecting container or the device for condensing water elimination are not damaged The discharge outlets are not blocked or obstructed The cabinet has been properly leveled 8 4 If the cabinet is unacceptably noisy make sure that The frame does not have loose screws or bolts The cabinet has been laid in a stable position and correc...

Страница 15: ...XISTING LOCAL STATUTES ARE THE RESPONSIBILITY OF THE OWER Meaning of crossed out wheeled dustbin Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact you local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwate...

Страница 16: ...14 Circuit diagram ...

Страница 17: ...cle from 65 C to 10 C t 90 min Blast freezing cycle from 65 C to 18 C t 270 min Contact details Yindu Kitchen Equipment Co Ltd No 1 Xingxing Road Xingqiao District Yuhang Hangzhou Zhejiang 311100 China Model EBF 03 EBF 05 Fast cooling performance per cycle kg 10Kg 90 3 in 90 Min 25Kg 90 3 in 90 Min Fast freezing performance per cycle kg 5Kg 90 18 in 240 Min 15Kg 90 18 in 240 Min Rated voltage 220 ...

Страница 18: ...load capacity 15 00 kg Refrigerant charge 0 15 kg Blast chilling cycle from 65 C to 10 C t 72 min Blast freezing cycle from 65 C to 18 C t 240 min Contact details Yindu Kitchen Equipment Co Ltd No 1 Xingxing Road Xingqiao District Yuhang Hangzhou Zhejiang 311100 China OFFICIAL APPROVAL AND RULES Our products full fill the present E U rules including the CE mark of the European official approval Ma...

Страница 19: ...17 Summary of operating parameters Signals on the display ...

Страница 20: ...event possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...

Отзывы: