23
The minimum cross-section of the yellow-green cable that is used to make the equipotential bond between the mass
of the storage system and the user's ground system must be:
•
greater than or equal to 2.5 mmq if the cable is mechanically protected
•
greater than or equal to 4 mmq if the cable is not mechanically protected.
In addition, the terminal that is connected to the screw on the frame of the storage system must have an eyelet
terminal with an 8 mm hole.
Picture 16 - Screw for the connection of the mass of the
storage system to the user's earthing system
3.3.3
Placement of the antenna
Move the antenna with magnet base from inside to outside the structure.
Picture 17 - Antenna
NOTE:
The antenna cable will have to pass through one of the pre-drilled slots on the back panel.
SCREW TO BE USED TO CONNECT THE MASS OF
THE MACHINE TO THE EARTH GROUNDING
SYSTEM