Atomic ATP5000XE Скачать руководство пользователя страница 2

2

TABLE OF CONTENTS

Safety Precautions .............................................. 2
Warranty and After Sales Service ...................... 3
Identification of Components ............................ 4
Pre-Operation Inspection ................................... 7
Operation ............................................................ 7
Assembly Instructions ........................................ 8
Starting & Stopping Generator ......................... 10
Maintenance ..................................................... 11
Air Filter Service ................................................ 12
Fuel Tap Sediment Bowl Service ...................... 12
Changing Engine Oil ......................................... 12
Spark Plug Service ............................................ 13
Spark Arrestor Service ...................................... 13
Handling and Storage ....................................... 13
Troubleshooting ................................................ 14
Specifications .................................................... 15

IMPORTANT INFORMATION

Thank you for purchasing this ATOMIC  
Power Gen Generator. 
This manual covers the safety, operation and 
maintenance procedures for the ATP5000XE  
and ATP6500XE.
All information in this publication is based on 
the latest product information available at the 
time of print. No part of this publication may be 
reproduced without written permission.
Please keep this manual together with  
the generator.
This generator is designed to give safe and 
dependable service if operated according to the 
user manual.
It is important that anyone operating this product 
read and understand the manual prior to use. 
Failure to do so could result in personal injury or 
equipment damage. 

SAFETY PRECAUTIONS

OPERATION SAFETY

•    Always perform a pre-operation check before 

starting the engine.

•    Properly clean and maintain the generator.
•    Operate the generator according to instructions 

for safe and dependable service.

•    Before operating the generator, read the user 

manual carefully. Otherwise, it may result in 
personal injuries or equipment damage.

Never run the generator indoors or in an 
enclosed area to avoid harm or possible death 
from exhaust emissions of poisonous carbon 
monoxide gas.
•    Be careful not to touch the exhaust system 

during operation because it can cause burns.

•    Pay attention to the warning labels because 

the engine exhaust system will become 
heated during operation and remain hot 
immediately after the engine is stopped.

•    Unleaded petrol is a highly flammable and 

explosive liquid. Refuel in a well ventilated 
area with the engine stopped.

•    When refuelling the generator, keep it  

away from cigarettes, open flames,  
smoke and/or sparks.

•    It is recommended that this generator not 

be connected for stand-by power to any 
household or building electrical circuit. 
Improper connections can allow electrical 
current from the generator to feed back into 
the utility lines and may electrocute persons 
contacting the lines during a power outage. 
When the utility power is restored, the 
generator may explode or cause fires.

•   Do not connect the generator to an ATS 

automatic transfer switch.

•    Place the generator at least 1 metre  

away from buildings or other equipment 
during operation.

•    Run the generator on a level surface. If the 

generator tilts, fuel spillage may result.

•    Know how to stop the generator quickly and 

understand the operation of all the controls. 
Never permit anyone to operate the generator 
without proper instructions.

JAM2013_atomic_TP_manual_ED3.indd   2

11/05/12   3:45 PM

Содержание ATP5000XE

Страница 1: ...USER MANUAL...

Страница 2: ...e Before operating the generator read the user manual carefully Otherwise it may result in personal injuries or equipment damage Never run the generator indoors or in an enclosed area to avoid harm or...

Страница 3: ...els electricity and machinery hazards should perform maintenance procedures WARRANTY STATEMENT Primus Australia warrants this product against defects for 12 months 500 hours whatever period expires fi...

Страница 4: ...P5000XE ATP6500XE FRONT ATP5000XE ATP6500XE REAR Air Filter Choke Lever Fuel Gauge Fuel Tap Anti sink Base Plate Recoil Starter Handle Oil Dipstick Front Panel Battery Spark Plug Carburettor Exhaust C...

Страница 5: ...ne oil or vegetable oils are not recommended CHECKING OIL LEVEL Remove the oil filler dipstick and clean Check the oil level by reinserting the oil filler dipstick Remove and examine the oil level If...

Страница 6: ...charge socket terminals can be used with the battery leads supplied to charge 12 volt automotive batteries only There is a DC12V reset button protecting the socket terminals If an overload is detected...

Страница 7: ...osite end of the handles using axle holder 10 Align the bolts 6 with the holes on the bottom of the generator and fasten tightly with the nuts 7 provided 5 Mount the hoist lift bracket assembly 17 to...

Страница 8: ...o the ON position The red indicator light on the RCD MCB housing panel will now illuminate 6 Lift up the clear front cover on the panel and push the switch up on the RCD MCB to the ON position The ON...

Страница 9: ...should be performed based on the following maintenance schedule GENERAL MAINTENANCE Check for leaks around the fuel tank fuel hose fuel tap and carburettor Check for exhaust leaks while the engine is...

Страница 10: ...before reassembling 5 Rotate fuel tap to ON and check for leaks After installing the sediment bowl tighten the O Ring securely Check for fuel leaks and remove any spilled fuel prior to starting CHANG...

Страница 11: ...e carbon deposits from spark arrestor screen Inspect the screen for holes and replace if necessary 4 Re install the spark arrestor HANDLING AND STORAGE When transporting the generator make sure to shu...

Страница 12: ...appliances from the front panel Engine is not starting No fuel Refill tank Fuel tap is closed Fully open fuel tap Fouled spark plug Remove clean or replace spark plug Not enough oil Add more oil Black...

Страница 13: ...H 9AH Engine type Single cylinder air cooled 4 stroke OHV 25 deg tilt Single cylinder air cooled 4 stroke OHV 25 deg tilt Engine model AG389 AG420 Rated power 13HP 15HP Max output kW rpm 7 8 3600 8 2...

Страница 14: ...14 Notes...

Страница 15: ...15...

Страница 16: ...Distributed by Primus Australia Pty Ltd Bundoora VIC 3083 www atomicgenerators com au JAM2013...

Отзывы: