12
TROUBLESHOOTING
Common issues can be fixed by following the
instructions in this guide. If the generator will
not operate normally after following these
instructions, contact an authorised dealer or
qualified technician before attempting to use
or carry out any repairs.
Many troubleshooting procedures present
hazards which can result in severe personal
injury or death. Only trained and experienced
service personnel with knowledge of fuels,
electricity, and machinery hazards should
perform service procedures. Review Safety
Precautions. A hot generator can cause severe
burns. Always allow the generator to cool
before performing any maintenance service.
ISSUE
CAUSE
ACTION
Engine cranks
slowly
Engine oil is too heavy
Replace with recommended oil
Load is connected
Disconnect all appliances from the front panel
Engine is
not starting
No fuel
Refill tank
Fuel tap is closed
Fully open fuel tap
Fouled spark plug
Remove, clean or replace spark plug
Not enough oil
Add more oil
Black
Exhaust
Choke stuck in closed position
Open choke
Dirty air cleaner
Clean air filter
Rich fuel mixture
Contact an authorised dealer
Engine
Stops
No fuel
Refill tank
Not enough oil
Add more oil
Engine has
difficulty
idling
Loose spark plug cable
Reconnect or repair cable
Faulty spark plug
Remove, clean or replace spark plug
Generator is not level
Move generator to a level surface
Dirty fuel filter
Replace the filter
No AC
Output
Tripped AC Circuit breaker
Disconnect all devices, reset breaker
and check devices for damage.
Do not exceed the generator load rating
No battery
charge
DC output
Corroded battery posts
Clean posts
Damaged cables
Replace cables
Damaged battery
Check for leaks, cracks and swelling,
replace if defective.
Damaged DC socket
Contact an authorised dealer
JAM2013_atomic_TP_manual_ED3.indd 12