- In case of malfunctioning under normal operation within one year from the
date of purchase, the machine will be repaired free of charge.
●
Product Replacement
- Products within one year from the date of purchase, with following conditions
· Malfunctioning under normal operation. Repaired but when the same
failure recurred.
· When repair is not possible
· If some critical parts need repairs
●
Non-warranty standard
· Malfunctioning due to user’s mistakes
· User negligence
· Natural disasters (Fire, salt damage, flood, earthquake, lightning, etc.)
· User’s carelessness
· If the product is not repaired at our service center, then an error has occurred
· If the product is arbitrarily disassembled or modified
· Malfunctioning due to the abnormal power supply or any other device
· If used beyond its intended purpose
· In case of consumable parts
· In case there is no name plate
· In case of using material flammable or which can deform the product
□
Warranty Standards
Please check the followings before calling the repair center.
When the machine is not working
●
Check if the power cord is plugged in.
●
Check if the electricity is connected to the electrical outlet.
●
Check if the voltage is 220V.
●
Check the fuse.
●
If the machine is not working even after the fuse is replaced, contact your
nearest dealer or the company.
●
If the suction hose inside the tank is clogged, remove the foreign substances.
●
Please note that heat is generated in the main body even during normal
operation.
●
If, during operation, some parts are deformed due to heat, please contact
the repair center.
In order to prevent accidents during operation, please read the user’s guide
before use.
●
Please use the electricity equipped with the grounded circuit breaker.
●
Do not use when the power line is wet. Do not touch the cord with wet hands.
●
Do not apply more than one plug in one electrical outlet.
●
Check the status of the power line before operation. If damaged, call the
certified technician for replacing the cord.
●
Always pull the plug out of the electrical outlet when the machine is disassembled
or not operated.
●
Disconnect power while the tank is charged.
●
When the machine is wet, never plug in the power. Let the wet parts replaced
by a certified technician.
●
For the additional cable, use the proper one equipped with ground connection.
●
Do not let somebody operate the machine without wearing the proper
protective equipment.
●
Do not spray toward humans, electric appliances, and the main body.
●
Keep away from children or unauthorized persons.
●
Always use the manufacturer-recommended parts for safety of the machine.
●
To prevent damage to the objects, keep a proper distance when sprayed
with its maximum.
●
Be careful of fire and shock.
●
Do not use water mixed with impurities, or flammable materials.
●
If there is unusual noise, smell or smoke in the machine, unplug immediately
and contact the A/S service center(There is a risk of fire or electric shock).
●
When cleaning the machine, unplug first, and do not use water or detergent.
●
Make sure to clean the tank after use, and keep away from children.
●
Keep the machine in a dry place away from the direct sunlight at 10~40℃.
□
Before Contacting the Repair Center
□
Precautions for use and storage
□
Storage Precautions
●
Chemicals
1. Considering the proper usage recommended by the supplier, plants and
working conditions, apply the chemicals.
2. In order to minimize the damage of the chemicals, the workers should wear
protective equipment like a gas mask.
●
Power line
1. It is convenient to have an additional power line of 150~200 meters
connected firmly to the main body according to working conditions.
2. For the additional power line, hire 250V/15A/3C(Earth) or higher.
3. Always be careful of the electric accidents as the work is usually done in
humid surroundings.
□
Tip for users
●
By spraying the ultra-fine particles, it is applied evenly to the entire object
due to the long suspension time and rotary atomization effect.
●
Rather than smoke or fume, the ultra-fine particles of the solution is sprayed
through the high speed rotating nozzle.
●
Consumption of solution is minimized while pest or diseases control effect is
maximized due to the spray system of the ultra-fine particles.
●
It relieves the fatigue of wrists by moving the injection nozzle up and down.
●
The built-in design of the injection nozzle makes its storage easy.
●
The speed, distance, and amount of spray is simply controllable.
●
It can be used for fumigation and sterilization in large buildings, offices,
toilets, public buildings, and hospitals.
□
Features
Warranty Complaints type
Compensation details
Within the warranty
period
After the warranty
period
In case of
malfunctioning
under
normal operation
Asking repair after purchase Repair free of charge Repair free of charge
Same failure recurred
(three times)
Product replacement
Non-warranty
Repair is not possible even
when parts are available
Product replacement
-
If repairs necessary on critical
parts after purchase
Product replacement
-
Malfunctioning
due to
user’s mistakes
When repair possible
Charged repair
Charged repair
When repair impossible
Charged replacement
-
▒ The Company is not responsible for accidents caused by customer’s mistakes.
▒ This guide is subject to change without a prior notice. Please check at the time of
purchase.
□
Part Drawing
□
Parts List
Module Name No
Part-Name
Spec.
CODE-NO Q’TY
Body set
1 Cover_L
APN-001
1
2 Cover_R
APN-002
1
4 Cover case_L
APN-004
1
5 Cover case_R
APN-005
1
8 Rack
APN-008
8
28 Spring
8-20
APN-028
8
39 Shoulder strap ring
APN-039
2
24 Shoulder strap pin
APN-024
1
Motor housing
set
3 Motor housing
APN-003
1
6 Motor housing cover
APN-006
1
31 O-ring
G-120
APN-031
1
Motor
13 Motor
1.4kW
APN-013
1
Tank set
9 Tank
APN-009
1
22 Water nipple
APN-022
1
23 Air nipple
APN-023
1
32 O-ring
G-45
APN-032
1
33 O-ring
P7
APN-033
1
34 O-ring
P10
APN-034
1
36 Flange nut
M8
APN-036
1
37 Flange nut
M10
APN-037
1
Module Name No
Part-Name
Spec.
CODE-NO Q’TY
Tank cap
7 Tank cap
APN-007
1
35 O-ring
AN325
APN-035
1
Valve
10 Valve
1/4
“
APN-010
1
Switch
11 Switch
100k
APN-011
1
12 Knob
Red
APN-012
1
Air nozzle
14 Air nozzle
APN-014
1
Nozzle set
15 Bel cup
APN-015
1
16 Bear housing
APN-016
1
17 Turbine
APN-017
1
18 Gasket
APN-018
1
19 Bearing bush
APN-019
1
20 Shaft
APN-020
1
21 Tube
APN-021
1
25 Bearing
S6901ZZ
APN-025
1
Fuse set
26 Fuse
5*20 10A APN-026
1
27 Fuse holder
5*20
APN-027
1
PCB
29 PCB
220V, 1.4kW APN-029
1
Power code 30 Power code
10A 6m
APN-030
1
Shoulder
strap
38 Shoulder strap
APN-038
1