3. Specification

MODEL

Max. capacity

(kg)

Min. weigh

(kg)

Division

(kg)

Total display

counts (n)

GSP911-30

30000

200

10

3000

GSP911-50

50000

400

20

2500

4. Appearance illustration

MODEL

Cap.(kg) A(mm) B(mm) C(mm) D(mm) E(mm) H(mm) N.W(kg) G.W.(kg

)

GSP911-30

30000

260

340

100

300

200

1055

105

115

GSP911-50

50000

360

600

110

440

320

1360

290

330

5. Power supply

Battery: 6V/7Ah fully sealed Lead-Acid battery

Adapter: 9VDC/1000mA adapter

Current: the crane scale average current is about DC 100mA±10%, if battery charged, it can be used
for about 70hours.Low battery warning: When the digits flash, it means the battery needs to be
recharged. The scale will power off automatically after 1 to 2 hours operation if the battery is not charged.
Please recharge the battery before operating the scale again.
Charging method: Turn off the crane scale, use adapter in the carton, the lamp on the back cover will
become orange when charging, and it will become green when the charging finish.
Generally, charging time should not less than 8hours, the crane scale have charging protection, long
time charging can’t damage the battery.

Digital Crane Scale

4

Automation       www.ato.com      [email protected]     Global Shipping      +1 800-585-1519 (Toll-free)

Содержание GSP911-30

Страница 1: ...DIGITAL CRANE SCALE USER MANUAL SKU ATO CRS 50T Digital Crane Scale Automation www ato com sales ato com Global Shipping 1 800 585 1519 Toll free...

Страница 2: ...ontrol 5 CHAPTER 3 OPERATION GUIDE 6 1 Turn on off 6 2 Zero 7 3 Tare 7 4 Hold 7 5 Accumulation 7 6 Accumulation Search 7 7 Accumulation Clear 8 8 Battery Voltage 8 9 Brightness 8 10 Zero Point 8 11 Un...

Страница 3: ...ery every three months to preserve the life span of the battery and recharge it before operation 5 The battery charger is included in the scale package Please use this charger It s normal that the cha...

Страница 4: ...Battery Operated with low battery indication Automatic turn off power saving function 2 Main technical data Standard According to OIML class III Display 45mm 1 8 5digits LED Zero Range 4 F S Tare Ran...

Страница 5: ...it can be used for about 70hours Low battery warning When the digits flash it means the battery needs to be recharged The scale will power off automatically after 1 to 2 hours operation if the batter...

Страница 6: ...2 Put the goods into container the scale will display goods net weight 3 If move goods and container the scale will display minus value of tare weight 4 REMOTE CONTROLLER Press any key on the remote...

Страница 7: ...ightness of LED 7 F2 Function Key used with F1 together 8 HOLD It used for hold function details see Chapter3 4 9 OFF Turn off the crane scale CHAPTER 3 OPERATION GUIDE express key on remote controlle...

Страница 8: ...n goods it will display net weight of goods 4 HOLD OPERATION ILLUSTRATION Press HOLD Hold the weight reading no matter load change Press HOLD again Return to normal weighing status 5 ACCUMULATION OPER...

Страница 9: ...should be between 5 8 and 6 9 if below than 5 8 the digits flash you need to recharge immediately 9 BRIGHTNESS OPERATION ILLUSTRATION F1 1 5 total 5 options from darkness to brightness Default is 3 1...

Страница 10: ...take cap 30000kg as example choose FS 30 Press TARE confirm Id 05 New scale the screen display Id 05 if scale calibrated the screen display calibrated division Press ZERO or CLEAR to choose Id 10 Choo...

Страница 11: ...if scale calibrated the screen display calibrated value Press ZERO or CLEAR to choose OFF 2 Choose turn off method 0 2 total 3 options 0 turn off by hand 1 if no operation the screen display after 15...

Страница 12: ...g 20000kg Second load must exceed Load 1 20 capacity Waiting until STB light on Press SHIFT 16000 Mention you Load2 must exceed 16000kg Press TARE ZERO CLEAR 20000 Input actual weight 20000kg waiting...

Страница 13: ...t be negative Waiting Err10 Weight less than Min Capacity Can t accumulate the value Err11 Accumulated times overflow Can t accumulate after 30times Err12 Accumulated weight overflow Can t accumulate...

Страница 14: ...or PCB Requires authorized service Load cell cable damaged Check and replace load cell Out of calibration Check calibration Display experiences excessive Zero drift between weighment Scale electronic...