2 ZERO

OPERATION

DISPLAY

When scale turn on, generally scale displays

0

,if

display small digits when no load, press this key.

Press

ZERO

0

3 TARE

TARE DIRECTLY

OPERATION

DISPLAY

After turn on, hanging tare weight such as sling, cable at
first, press this key, “TARE” light on, then the scale will
display net weight of the goods.

1

Press TARE

0

2

Press

TARE

0

SET TARE WEIGHT IN ADVANCE

OPERATION

DISPLAY

ILLUSTRATION

SHIFT

】【

TARE

0000.0

Current tare weight

TARE

】【

ZERO

】【

CLEAR

xxx

Set known tare weight,

TARE

used to move

digit,

ZERO

】【

CLEAR

used to set value.

SHIFT

- xxx

exit, “TARE” light on, it displays minus tare

weight, after hanging on goods, it will display
net weight of goods.

4 HOLD

OPERATION

ILLUSTRATION

Press

HOLD

Hold the weight reading no matter load change

Press

HOLD

again

Return to normal weighing status

5 ACCUMULATION

OPERATION

DISPLAY

ILLUSTRATION

Press

ACCU

No***

Current accumulation time

H****

Front four digits of total value

L****

Rear four digits of total value

After display above contents two times, the scale will return automatically, you also can press

SHIFT

to return.

6 ACCUMULATION SEARCH

OPERATION

DISPLAY

ILLUSTRATION

SHIFT

ACCU

】 〖

No.***

Current accumulation time

*****

Current weight reading

H****

Front four digits of total value

L****

Rear four digits of total value

SHIFT

*****

Return

Press

TARE

and

ZERO

can check different times weight and accumulation.

Digital Crane Scale

7

Automation       www.ato.com      [email protected]     Global Shipping      +1 800-585-1519 (Toll-free)

Содержание GSP911-30

Страница 1: ...DIGITAL CRANE SCALE USER MANUAL SKU ATO CRS 50T Digital Crane Scale Automation www ato com sales ato com Global Shipping 1 800 585 1519 Toll free...

Страница 2: ...ontrol 5 CHAPTER 3 OPERATION GUIDE 6 1 Turn on off 6 2 Zero 7 3 Tare 7 4 Hold 7 5 Accumulation 7 6 Accumulation Search 7 7 Accumulation Clear 8 8 Battery Voltage 8 9 Brightness 8 10 Zero Point 8 11 Un...

Страница 3: ...ery every three months to preserve the life span of the battery and recharge it before operation 5 The battery charger is included in the scale package Please use this charger It s normal that the cha...

Страница 4: ...Battery Operated with low battery indication Automatic turn off power saving function 2 Main technical data Standard According to OIML class III Display 45mm 1 8 5digits LED Zero Range 4 F S Tare Ran...

Страница 5: ...it can be used for about 70hours Low battery warning When the digits flash it means the battery needs to be recharged The scale will power off automatically after 1 to 2 hours operation if the batter...

Страница 6: ...2 Put the goods into container the scale will display goods net weight 3 If move goods and container the scale will display minus value of tare weight 4 REMOTE CONTROLLER Press any key on the remote...

Страница 7: ...ightness of LED 7 F2 Function Key used with F1 together 8 HOLD It used for hold function details see Chapter3 4 9 OFF Turn off the crane scale CHAPTER 3 OPERATION GUIDE express key on remote controlle...

Страница 8: ...n goods it will display net weight of goods 4 HOLD OPERATION ILLUSTRATION Press HOLD Hold the weight reading no matter load change Press HOLD again Return to normal weighing status 5 ACCUMULATION OPER...

Страница 9: ...should be between 5 8 and 6 9 if below than 5 8 the digits flash you need to recharge immediately 9 BRIGHTNESS OPERATION ILLUSTRATION F1 1 5 total 5 options from darkness to brightness Default is 3 1...

Страница 10: ...take cap 30000kg as example choose FS 30 Press TARE confirm Id 05 New scale the screen display Id 05 if scale calibrated the screen display calibrated division Press ZERO or CLEAR to choose Id 10 Choo...

Страница 11: ...if scale calibrated the screen display calibrated value Press ZERO or CLEAR to choose OFF 2 Choose turn off method 0 2 total 3 options 0 turn off by hand 1 if no operation the screen display after 15...

Страница 12: ...g 20000kg Second load must exceed Load 1 20 capacity Waiting until STB light on Press SHIFT 16000 Mention you Load2 must exceed 16000kg Press TARE ZERO CLEAR 20000 Input actual weight 20000kg waiting...

Страница 13: ...t be negative Waiting Err10 Weight less than Min Capacity Can t accumulate the value Err11 Accumulated times overflow Can t accumulate after 30times Err12 Accumulated weight overflow Can t accumulate...

Страница 14: ...or PCB Requires authorized service Load cell cable damaged Check and replace load cell Out of calibration Check calibration Display experiences excessive Zero drift between weighment Scale electronic...