Safety instructions

•  Check all adjustable parts are locked, 

before every use of the aid.

•  The brakes must be applied when the 

device is switched off or not in use.

•  Apply the lever brakes for a secure stand 

when stopping.

•  Always lock brakes before use, when 

setting, adjusting functions or accessories.

•  Please note the individual and overall 

safety relevant information when using 
several rehabilitation aids simultaneously.

•  All aspects of spatial influences (uneven, 

wet and smooth floors, steps or similar) 
must be taken into consideration by the 
carer or user.

•  Do not use the CareWell MobiCare 

before checking the wheels of the aid.

•  Wet and dirtied wheels can decrease the 

braking effect.

•  Check regularly if all screws and handles 

etc. are firmly tightened. Worn and 
defect parts are to be repaired or replaced 
immediately. This is especially important 
to ensure a safe use of the rehab aid! 
Carefully check the clamping jigs and the 
like are securely fixed.

•  Do not use the aid, if parts of it are 

damaged or missing. Missing parts are 
only to be replaced with original spare 
parts.

•  Do not carry out any interferences or 

measurements if you are unsure of their 
effects. For your own safety contact the 
nearest service centre or contact the 
dealer directly.

•  In case of accidents or malfunctions, 

contact the dealer or manufacturer from 
whom you purchased the device.

•  The manufacturer is not liable for damage 

to persons, objects or animals resulting 
from false usage of the equipment by the 
user or third parties, through incorrect 
mounting of parts and accessories, by 
neglect or poor maintenance, neglect, 
through unauthorized alterations and 
modifications, usage of non-original 
spare parts or accessories, through 
unpredictable and exceptional events 
resulting from non-compliance of the 
regulations in the presented operating 
manual.

•  Clean the Changing bench CareWell 

MobiCare in accordance with the 
instructions given in the chapter 
„cleaning”.

•  Please ensure before use the product 

is cleaned according to the cleaning 
instructions and if indicated also 
disinfected. 

•  Any serious incidents occurring in 

connection with the product must be 
reported to the manufacturer (ATO 
FORM GmbH) and the competent 
authority of the country in which the user 
is resident.

Содержание CareWell MobiCare

Страница 1: ...User manual Series CareWell universal transfer and changing bench MobiCare Bath and wc edition 24 21...

Страница 2: ......

Страница 3: ...hanging bench CareWell MobiCare distinguishes itself by its quality security easy operation and modern design For optimal use of this aid we ask you and possible other users to carefully read this ope...

Страница 4: ...7 Purpose of use 10 8 Product overview 11 8 1 Basic model 11 8 2 Accessories options 12 9 Initial operation 13 10 Assembly and adjustment 14 10 1 Basic model 14 11 Types and accessories 18 11 1 Basic...

Страница 5: ...taff with the experience and knowledge of operators which they gained from for example training courses In the event of specific or difficult applications the user manual represents a guide to the mos...

Страница 6: ...to change previous devices and associated operating manuals The Changing bench CareWell MobiCare must only be operated under supervision of a qualified person or respectively a family member of the us...

Страница 7: ...g parts are only to be replaced with original spare parts Do not carry out any interferences or measurements if you are unsure of their effects For your own safety contact the nearest service centre o...

Страница 8: ...Page 8 32 24 21 We constantly develop new aids and improve existing products We are happy to receive your suggestions of every description Safety instructions...

Страница 9: ...to normal wear and tear and need periodic replacement The warranty is null and void if non original ATO FORM parts accessories are used or if the product is repaired or altered by anyone other than a...

Страница 10: ...adjustments of the aid according to the measurements of the user Only compliance of the regulations and instructions can lead to positive ergo nomically effects We wish you every success when using t...

Страница 11: ...t overview 1 Basic frame with safety skirt 2 Safety casters individually lockable 3 Battery unit 4 Control box 5 Remote control 6 Paper roll holder 7 Side rails 8 CE label 8 Product overview 8 1 Basic...

Страница 12: ...cessories options According to the current status there are no accessories for this product available For a complete overview of our extensive range of accessories for the CareWell Mo biCare see item...

Страница 13: ...elp of the reseller the user as well as the attendant must become famil iar with the correct operation of the aid Once the demonstration has been complet ed the reseller must ensure the user and or th...

Страница 14: ...epending on the user weight at max imum weight a maximum of one lift is recommended then charge for 6 hours Buzzer function The buzzer issues a warning if a button on the hand control is pressed and t...

Страница 15: ...ard completely under the lying surface LED operation display Solid yellow Charging battery not ready LED is off fully charged battery ready The charger integrated in the battery unit is only supplied...

Страница 16: ...nt from a wheelchair Lift the side guard and fold it down Store the side guard under the table Move the table down to the height of the wheel chair seat Now you can easily relocate the patient Moving...

Страница 17: ...aper roll holder can accommodate a paper roll with a length of 70 0 cm an inner diameter of at least 2 2 cm and an outer diameter of maximum 14 5 cm For this purpose loosen the screws A on the paper r...

Страница 18: ...changing bench CareWell MobiCare 1600 laying surface 160 x 75 cm basic frame steel powder coated CW MC 1800E Mobile changing bench CareWell MobiCare 1800 laying surface 180 x 75 cm basic frame stainle...

Страница 19: ...re Well MobiCare and their description as well as much more useful information can be found on our homepage www ato form com For special problems or if it seems the accessories you require are not dem...

Страница 20: ...90 5 55 5 to 90 5 E Width safety side rails cm 140 7 140 7 140 7 160 7 F Hight safety side rails cm 16 5 16 5 16 5 20 0 G Distance between castors length cm 108 0 108 0 108 0 140 0 H Distance between...

Страница 21: ...and version The padded surface is made of fireproof synthetic leather PVC Operating conditions Standby power consumption approx 0 5 W 230 V Duty cycle maximum 10 or 2 minutes use then 18 minutes break...

Страница 22: ...gularly remove dust hairs and other accumulating dirt from rollers Cleaning of textiles and imitation leather These are best cleaned using water and a mild detergent When using the cleaning agents the...

Страница 23: ...Page 23 32 24 21...

Страница 24: ...nance works for your CareWell MobiCare The device should be checked by the manufacturer at the latest after 5 years 14 Maintenance and overhaul Maintenance Checklist Castors No damage or wear Firm sea...

Страница 25: ...Page 25 32 24 21 Date Service performed Name Sign Maintenance and overhaul...

Страница 26: ...g to the instructions given in our user manual The expected operating life does not apply to wear parts The product CareWell MobiCare was designed so it could be reused after the application of variou...

Страница 27: ...s and original spare parts may be used Non compliance with these instructions and repairs carried out or modifications made to the CareWell MobiCare or its parts by unauthorized persons voids any warr...

Страница 28: ...u or care and maintenance staff have access to it 17 Storage The current version of these instructions for use can be found on our homepage in the download area You can find more informati on about th...

Страница 29: ...Page 29 32 24 21...

Страница 30: ...Page 30 32 24 21...

Страница 31: ...of PE and are therefore low in pollutant and can either be recycled or burnt 2021 24 St I 2021 23 Disposal of battery operated devices The battery pack must not be disposed of together with normal ho...

Страница 32: ...mized solutions Thank you for your interest in our products For questions please contact ATO FORM GmbH or your specialist dealer Your ATO FORM Team ATO FORM GmbH Zur Lauterhecke 34 63877 Sailauf Germa...

Отзывы: