ato form CareWell MobiCare Скачать руководство пользователя страница 6

Page  6/32 (24/21)

•   Before mounting or using the Changing 

bench CareWell MobiCare carefully 
read all instructions of this user manual, 
as these have been drawn up for your 
safety and as a guideline for the correct 
use and maintenance of this product. 
This operating manual is an indispensable 
component of the delivery and should be 
stored carefully for further use.

•  The operating manual is intended for 

retailers and users of the Changing bench 
CareWell MobiCare, (or their carers). 
It contains the required information to 
secure the correct use of the product, it 
cannot, however replace the necessary 
experience of the user or assistant in 
handling the device.

•   The reseller has the duty to deliver the 

device ready for operation and to explain 
precisely the functions and technical 
data of the device, as well as provide the 
necessary support and briefing needed for 
a correct and efficient use of the device.

•  The given instructions of the operating 

manual, refers to the point in time of 
the device being placed on the market. 
The manufacturer reserves the right to 
introduce any modifications which prove 
necessary to the device and associated 
operating manual, without being bound 
to change previous devices and associated 
operating manuals.

•  The Changing bench CareWell MobiCare 

must only be operated under supervision 
of a qualified person, or respectively a 
family member of the user.

•  Never leave the user of the aid 

unattended.

•  The CareWell MobiCare may only 

be operated by persons who have 
familiarized themselves with the standards 
and rules of the present operating 
manual.

•  The CareWell MobiCare may only be 

used by persons of a suitable stature and 
physical aptitude.

•  Never place a patient in an aid, which 

is not coordinated with his or hers body 
height and weight.

•  Adjust settings only in the unloaded 

condition.

•  Do not place any hot beverages or objects 

onto the aid you have purchased, as this 
would seriously damage the aid.

•  Do not load any heavy objects onto the 

aid, as this would impair the structure, the 
centre of gravity and consequently impair 
the balance.

•  Always ensure there are no obstacles in 

operating range of the rehab aid, such 
as carpets, stairs or objects on the floor, 
which could lead to the Changing bench 
CareWell MobiCare overturning.

•  Move all objects out of the way, which 

could be hit or fall whilst operating the 
aid.

•  Never use the aid on rough terrain, 

steeply sloping ground or stairs. 

•  Do not use the rehab aid before ensuring 

a complete and correct fitting of the 
safety belts, if available.

Safety instructions

Safety instructions

Содержание CareWell MobiCare

Страница 1: ...User manual Series CareWell universal transfer and changing bench MobiCare Bath and wc edition 24 21...

Страница 2: ......

Страница 3: ...hanging bench CareWell MobiCare distinguishes itself by its quality security easy operation and modern design For optimal use of this aid we ask you and possible other users to carefully read this ope...

Страница 4: ...7 Purpose of use 10 8 Product overview 11 8 1 Basic model 11 8 2 Accessories options 12 9 Initial operation 13 10 Assembly and adjustment 14 10 1 Basic model 14 11 Types and accessories 18 11 1 Basic...

Страница 5: ...taff with the experience and knowledge of operators which they gained from for example training courses In the event of specific or difficult applications the user manual represents a guide to the mos...

Страница 6: ...to change previous devices and associated operating manuals The Changing bench CareWell MobiCare must only be operated under supervision of a qualified person or respectively a family member of the us...

Страница 7: ...g parts are only to be replaced with original spare parts Do not carry out any interferences or measurements if you are unsure of their effects For your own safety contact the nearest service centre o...

Страница 8: ...Page 8 32 24 21 We constantly develop new aids and improve existing products We are happy to receive your suggestions of every description Safety instructions...

Страница 9: ...to normal wear and tear and need periodic replacement The warranty is null and void if non original ATO FORM parts accessories are used or if the product is repaired or altered by anyone other than a...

Страница 10: ...adjustments of the aid according to the measurements of the user Only compliance of the regulations and instructions can lead to positive ergo nomically effects We wish you every success when using t...

Страница 11: ...t overview 1 Basic frame with safety skirt 2 Safety casters individually lockable 3 Battery unit 4 Control box 5 Remote control 6 Paper roll holder 7 Side rails 8 CE label 8 Product overview 8 1 Basic...

Страница 12: ...cessories options According to the current status there are no accessories for this product available For a complete overview of our extensive range of accessories for the CareWell Mo biCare see item...

Страница 13: ...elp of the reseller the user as well as the attendant must become famil iar with the correct operation of the aid Once the demonstration has been complet ed the reseller must ensure the user and or th...

Страница 14: ...epending on the user weight at max imum weight a maximum of one lift is recommended then charge for 6 hours Buzzer function The buzzer issues a warning if a button on the hand control is pressed and t...

Страница 15: ...ard completely under the lying surface LED operation display Solid yellow Charging battery not ready LED is off fully charged battery ready The charger integrated in the battery unit is only supplied...

Страница 16: ...nt from a wheelchair Lift the side guard and fold it down Store the side guard under the table Move the table down to the height of the wheel chair seat Now you can easily relocate the patient Moving...

Страница 17: ...aper roll holder can accommodate a paper roll with a length of 70 0 cm an inner diameter of at least 2 2 cm and an outer diameter of maximum 14 5 cm For this purpose loosen the screws A on the paper r...

Страница 18: ...changing bench CareWell MobiCare 1600 laying surface 160 x 75 cm basic frame steel powder coated CW MC 1800E Mobile changing bench CareWell MobiCare 1800 laying surface 180 x 75 cm basic frame stainle...

Страница 19: ...re Well MobiCare and their description as well as much more useful information can be found on our homepage www ato form com For special problems or if it seems the accessories you require are not dem...

Страница 20: ...90 5 55 5 to 90 5 E Width safety side rails cm 140 7 140 7 140 7 160 7 F Hight safety side rails cm 16 5 16 5 16 5 20 0 G Distance between castors length cm 108 0 108 0 108 0 140 0 H Distance between...

Страница 21: ...and version The padded surface is made of fireproof synthetic leather PVC Operating conditions Standby power consumption approx 0 5 W 230 V Duty cycle maximum 10 or 2 minutes use then 18 minutes break...

Страница 22: ...gularly remove dust hairs and other accumulating dirt from rollers Cleaning of textiles and imitation leather These are best cleaned using water and a mild detergent When using the cleaning agents the...

Страница 23: ...Page 23 32 24 21...

Страница 24: ...nance works for your CareWell MobiCare The device should be checked by the manufacturer at the latest after 5 years 14 Maintenance and overhaul Maintenance Checklist Castors No damage or wear Firm sea...

Страница 25: ...Page 25 32 24 21 Date Service performed Name Sign Maintenance and overhaul...

Страница 26: ...g to the instructions given in our user manual The expected operating life does not apply to wear parts The product CareWell MobiCare was designed so it could be reused after the application of variou...

Страница 27: ...s and original spare parts may be used Non compliance with these instructions and repairs carried out or modifications made to the CareWell MobiCare or its parts by unauthorized persons voids any warr...

Страница 28: ...u or care and maintenance staff have access to it 17 Storage The current version of these instructions for use can be found on our homepage in the download area You can find more informati on about th...

Страница 29: ...Page 29 32 24 21...

Страница 30: ...Page 30 32 24 21...

Страница 31: ...of PE and are therefore low in pollutant and can either be recycled or burnt 2021 24 St I 2021 23 Disposal of battery operated devices The battery pack must not be disposed of together with normal ho...

Страница 32: ...mized solutions Thank you for your interest in our products For questions please contact ATO FORM GmbH or your specialist dealer Your ATO FORM Team ATO FORM GmbH Zur Lauterhecke 34 63877 Sailauf Germa...

Отзывы: