4-8
4.2. TROUBLESHOOTING
4.2.1. GENERAL
This section contains information for locating and removal most of
the PS-27 operating troubles which may occur. Each malfunction
for an individual component or assembly is followed by a list of tests
or inspections that will help determine probable causes and cor-
rective action to take. Perform the tests/ inspections and corrective
actions in the order listed.
This manual cannot list all possible malfunctions that may occur,
or all tests or inspections and corrective actions. If a malfunction
is not listed (except when malfunction and cause are obvious), or
is not corrected by listed corrective actions, contact to the service
center.
4.2.2. TROUBLESHOOTING PROCEDURES
Troubleshooting procedures are listed in Table 4-2.
Table 4-2. Troubleshooting Procedures
PROBLEM
PROBABLE CAUSE
CORRECTIVE ACTION
Sight will not
come on.
Battery is miss-
ing or improperly
installed.
Insert battery or install
correctly.
Battery is dead.
Replace battery.
Battery contact
surfaces or contact
springs dirty or cor-
roded.
Clean the contact
surfaces with a pencil
eraser and/or alcohol
and cotton swabs.
Defective image
tube.
Send the sight to the
service center.
Содержание PS-27
Страница 7: ...1 1 SECTION I introduction...
Страница 17: ...2 1 SECTION II operating instructions...
Страница 31: ...3 1 SECTION III OPERATIONAL DEFECTS...
Страница 37: ...4 1 SECTION IV maintenance instructions...
Страница 43: ...4 7 Figure 4 1 Focusing Assembly Threaded Ring Driving Ring Locking Ring M3x6 Screw M2 5x4 Screw...
Страница 50: ...A 3 4 3 5 Figure A 2 Accessories 1 From the Kit Figure A 3 Accessories 2 Optional 1 1 2 2 3 4 7 8 5 6...
Страница 54: ...INFO 2...
Страница 55: ...INFO 3...