7.5. Connecting the flue system.
Prior to connection of the boiler's flue system please
refer to sections 6.3 & 6.4 of these instructions.
The flue and air duct supplied by Atmos Heating
Systems are an integral part of the boiler and care
must be taken on their installation to ensure that all
joints are airtight and correctly made.
The standard horizontal flue kit supplied with
the boiler consists of a twin pipe terminal plate,
an 850mm length of 80mm diameter aluminium
duct and two 90º bends.
The flue and air ducts may be extended by
means of extensions, (available on request from
Atmos Heating Systems) to a maximum
combined length of 64m. The use of each
additional 90° or 45° bend however, reduces
the maximum permitted flue length by 3m and
1m respectively.
The duct and fittings are push fitted together being
sealed by the fittings integral 'O' ring. (fig 12).
On assembly it must be ensured that aluminium duct
is square and burr free prior to being pushed into
the fitting. Failure to do so may result in damage to
the sealing 'O' ring.
When connecting to the twin pipe terminal plate it is
important to ensure that the plate is fitted the
correct way up and the flue discharge and air inlet
ducts are connected to the correct terminal. (fig 13)
On installing the flue system it is recommended that
a 85mm diameter core drill is used when cutting
through the properties external wall.
For concentric and vertical roof systems refer to
separate installation instructions supplied with the
flue assemblies.
Figure 12: Twin pipe joint
Figure 13: Twin pipe terminal plate