6.6 Existing systems.
All re-circulatory water systems are subject to
corrosion unless an appropriate water treatment is
applied. To prevent the risk of corrosion sludge
accumulates within an existing system causing
boiler noise and circulation problems along with
possible pump and valve damage, existing heating
systems must be thoroughly flushed to ensure that
all sludge and debris is removed prior to installing
the boiler.
Where a cleaning agent is used for this purpose
only Sentinel X400 is recommended. Atmos Heating
Systems do not recommend the any other cleaning
agent. The use of non-recommended cleaning
agents will invalidate the boiler's guarantee.
Note. When after flushing and cleaning of the
system has taken place there is any possibility of
any debris remaining in the system, it is
recommended that a 'Y' strainer is fitted on the boiler
Return pipe.
7. Boiler Installation.
7.1 Unpacking
Due to the boilers dry weight of 75kg it is
recommend that either a sack barrow or two men are
employed to carry the boiler to its chosen position.
The boiler must be carried and stored horizontally
on the wooden pallet provided. Under no
circumstances must it be stored vertically.
The appliance is protected by a cardboard box and
delivered as standard with:
q
Mounting bracket
q
Fixing pack consisting of 2 wall plugs, 2 bolts
and 2 washers
q
Burner inspection window
q
Automatic de-aerator
q
Siphon
q
Template
q
Guarantee registration card, Operating
instructions and Installation instructions
In addition the boiler is supplied with;
q
WRAC mains water kit including UV3 cold
water inlet manifold, an 8 litre blue expansion
vessel, safety valve and pipe connections and;
q
Robokit sealed system expansion vessel
including wall bracket and safety valve.
Using a knife, cut open the bottom tray of the box
and remove the top box from the bottom tray (fig. 7).
Figure 7: Unpacking boiler
Check the appliance immediately after unpacking.
Any damage must be reported immediately to your
supplier.
The packaging consists of corrugated cardboard,
wood and cellulose oil, and can therefore be
recycled as waste paper. Do not throw away the
packaging, but ask the local refuse collection
service where it can be taken.
Remove the appliance casing to prevent accidental
damaged during installation as follows (fig. 8):
i) Remove the two screws 'a' of the control panel.
ii) Unclick the catches 'b' at the top and bottom of
the appliance and remove case by lifting upwards.