Ref.:
UoD_SpW-10X_
UserManual
Issue:
3.4
SpW-10X
SpaceWire Router
User Manual
Date:
11
th
July 2008
Preliminary
110
Table 9-5 Configuration Port Control/Status Register Fields
Bits Name
Reset
Value
Description Read/Write
0
Error active
‘0’
The error active bit is set when one of the error
bits is active
R
1
Port timeout error
‘0’
The port timeout error bit is set when a timeout
event is detected by the configuration port
routing logic.
R
2 Invalid
Header
CRC
‘0’
The Invalid header CRC bit is set when the
header CRC is invalid.
R
3
Invalid Data CRC
‘0’
The invalid data CRC is set when the data part
of the packet is corrupted and the CRC does
not match the internally generated CRC.
R
4 Invalid
Destination
Key
‘0’
The invalid destination key bit is set when the
destination key in the command packet is
invalid.
R
5 Command
not
implemented
‘0’
The command not implemented bit is set when
the command code is a valid RMAP code but
the command is not supported by the
SpaceWire Router.
R
6
Invalid Data Length ‘0’
The invalid data length bit is set when a data
length error is detected
R
7 Invalid
RMW
Data
Length
‘0’
The read modify write command data length is
invalid. When a read modify write is performed
the expected data length is 8.
R
8 Invalid
Destination
Logical Address
‘0’
The invalid destination logical address bit is set
when the destination logical address in the
command packet is not the default value of
254.
R
9
Early EOP
‘0’
The early EOP bit is set when the command
packet is terminated before the end of packet
with an EOP
R
10
Late EOP
‘0’
The late EOP bit is set when the command
packet is not terminated correctly and trailing
bytes are detected before the end of packet.
R
11
Early EEP
‘0’
The early EEP bit is set when the command
packet is terminated before the end of packet
with an EEP
R
12
Late EEP
‘0’
The late EEP bit is set when the command
packet is not terminated correctly and trailing
bytes are detected before the end of packet.
R
13 Verify
Buffer
Overrun Error
‘0’
The verify buffer overrun error bit is set when a
verified write command is performed and the
data length is not 4.
R