AVR
®
ATICE10 User Guide
7-1
Section 7
Troubleshooting Guide
Table 7-1.
Troubleshooting
Problem
Solution
The red LED is not lit when
the power is turned on
- Check that the power cord is properly inserted in the wall
- Check that the power plug is properly inserted in the ICE
- Check that you are using a power supply with negative center
on the DC output
When a file is opened in
AVR Studio, it starts in
simulator mode
- Check that the serial cable is inserted in the PC and the ICE
- Restart the PC with the ICE serial cable connected to the
serial port to make sure no other devices (mouse, etc.) are
using the serial port
- Disconnect the pod from the emulator and restart the
emulator
After performing an upgrade
of the ICE from AVR Studio,
the green LED is not lit when
the power is turned on
- Wait 10 seconds
- Restart the emulator
- Perform the upgrade again
The application is not
running in AVR Studio
- Make sure the target V
CC
is connected or that the application
is powered by the emulator
- Make sure the target clock is connected or internal clock is
selected in AVR Studio
- Disconnect the pod and try again; if it is working now, the
problem is in the application
AVR Studio shows the
message “Error
communicating with the
emulator” when trying to
download the code
- Check serial cable connections
- Make sure the pod is correctly connected to the emulator and
the target
- Make sure the target power is present (LED lit on the pod)
- Restart the emulator
Содержание AVR ATICE10
Страница 1: ...ATICE10 User Guide ...
Страница 2: ......
Страница 6: ...Table of Contents iv AVR ATICE10 User Guide ...
Страница 10: ...Introduction 1 4 AVR ATICE10 User Guide ...
Страница 20: ...Using the ICE10 3 6 AVR ATICE10 User Guide ...
Страница 32: ...Troubleshooting Guide 7 2 AVR ATICE10 User Guide ...