AT-OPUS-RX41
13
Installation
IR Control
OPTIONAL
RX TX
TX RX
INPUT
4
3
2
1
HDMI OUT
DC 5V
LAN
RX
S
TX
RS-232
IR IN
OPTICAL
HDBaseT
RS-232
IR
1
2
3
4
INPUT
INPUT
POWER
FW
AT-OPUS-RX41
OPUS
TM
The 5-pin
HDBaseT RS-232/IR
port provides bidirectional RS-232 control of a headend matrix (transmitter) over
HDBaseT. The 4-pin
RS-232/IR IN
port allows RS-232 control of the AT-OPUS-RX41.
1.
Locate the required captive screw connector (included in the box).
2.
Use wire strippers to remove a portion of the cable jacket.
3.
Remove at least 3/16” (5 mm) of insulation from each of the wires.
4. Insert the wires into correct terminal. Refer to
Figure 1.1
,
Figure 2.2
, or
Figure 1.2
, below.
5.
Connect the captive screw block to the proper port.
Figure 2.1
- Wiring the 5-pin HDBaseT RS-232/IR
captive screw block to have a controller at the viewing
location send IR commands over HDBaseT to an IR
emitter
Figure 2.3
- Wiring the 4-pin HDBaseT RS-232/IR IN
captive screw block to control the AT-OPUS-RX41 over
IR.
Figure 2.2
- Wiring the 5-pin HDBaseT RS-232/IR
captive screw block to send IR commands over an IR
emitter, from a control system, placed remotely at the
transmitter side.
TX
GND
to control system
S
to control system
GND
RX
GND
to IR emitter