AT-OME-SR21

Audio

Connect to an audio DSP, amplifier, or other 

audio distribution devices. 

RS-232

A 3-pin captive screw connector has been 

included for RS-232.

Pin out will be determined by the RS-232 cable 

and connect as RX (receive), TX (transmit) and      

(Ground). Ground will be shared between port 1 

and port 2. 

GND

RX

TX

GND

RX

TX

RX

TX

1

2

Use a jumper between the negative and 

ground pins when using an unbalanced 

connection.

Balanced

Unbalanced

ANALOG IN

L

R

Negative

Negative

+

Positive

+

Positive

Gr

ound

ANALOG IN

L

R

+

Positive

+

Positive

Gr

ound

Relay

A dual low-voltage signal relay is built into 

the OME-SR21 for control of devices such 

as electric screens and display lifts.  A 3-pin 

captive screw connector has been included 

for connection.

When using a dual signal relay with an electric 

projection screen, it allows for two different 

circuits to be controlled: up and down 

(pictured to the right)

.

The relay will default to follow the display. When 

the unit turns on the relay will close C1 and 

open C2. When the display is turned off and 

signal is no longer being received C1 will open 

and C2 will close. 

There are 3 connections for the relay: C1, COM, 

and C2 (Circuit 1, Common, and Circuit 2.)

C2

C1

COM

C1

C1

C2

C2

COM

COM

Down

Closed

Open

Open

Closed

Up

NOTE:

 Port 1 is for unit control and port 

2 will control the display.

Содержание AT-OME-SR21

Страница 1: ...s microphones speakers DSPs and touch or interactive displays The OME SR21 is ideal for 4K presentation applications with Omega HDVS 200 or UHD EX Series transmitters as well as Atlona AV presentation switchers with HDBaseT outputs local HDMI sources and the Gain Series amplifiers The OME SR21 combines the benefits of 4K UHD scaling auto switching for HDBaseT and HDMI inputs integrated display con...

Страница 2: ...sb camera mouse etc 7 HOST USB Connect to a computer using a USB B to USB A cable 8 LINK LED Illuminates yellow when receiving signal from the HDBaseT input port 9 IP MODE button and LED Press and hold the button for 5 seconds until the LED blinks to switch the IP mode between DHCP and Static IP modes The LED will blink 2 times for DHCP and 3 times for static IP 10 HDBaseT IN Connect a compatible ...

Страница 3: ...A dual low voltage signal relay is built into the OME SR21 for control of devices such as electric screens and display lifts A 3 pin captive screw connector has been included for connection When using a dual signal relay with an electric projection screen it allows for two different circuits to be controlled up and down pictured to the right The relay will default to follow the display When the un...

Страница 4: ...EGA TM INPUT PATTERN DEVICE IP Mounting Instructions The AT OME SR21 includes two mounting brackets and four mounting screws which can be used to attach the units to any flat surface 1 Remove the top 2 case screws on the side of the unit 2 Align the mounting brackets to the side of the units 3 Use the previously removed case screws to secure the mounting bracket to the enclosure 4 Repeat the steps...

Страница 5: ...local display to pass through Ethernet 10 Optional To control devices such as electric screens and display lifts connect the device to the 3 pin captive screw relay port 11 Connect the included DC 24V power supply to the power port 12 Connect the included IEC power cord from the power supply to a compatible power outlet Installation Refer to the tables below for recommended cabling when using Alto...

Страница 6: ...Network LAN it will automatically be assigned an IP address by the DHCP server if available Press the DEVICE IP button to show the IP address in the top left corner of the display IP Accessing the webGUI The AT OME SR21 includes a built in webGUI which allows easy remote management and control of all features Follow the instructions below to access the webGUI 1 Make sure that an Ethernet cable is ...

Страница 7: ... download or the easy to install server hardware AT AMS HW Once AMS has been set up 1 Open a browser on the same network as AMS 2 0 and go to the IP address of AMS 2 0 View the AMS 2 0 installation instructions on how to find the IP address of the software 2 Enter the login information on the AMS 2 0 web page then click the Login button 3 View the AT OME SR21 manual for routing and configuration i...

Страница 8: ...na Inc All other brand names and trademarks or registered trademarks are the property of their respective owners Pricing specifications and availability subject to change without notice Actual products product images and online product images may vary from images shown here Toll free US International atlona com 877 536 3976 41 43 508 4321 ...

Отзывы: