Introduction

The 1544ZOP 4x4 Smart Zone Output Processor provides all the network audio routing and zone digital signal processing functions of a DNA2404D 
integrated network amplifier unit. This includes Dante network audio input, equalization, level control, and IED’s patented AlwaysHEAR™ smart 
ambient analysis automatic level adjustment. The 1544ZOP provides four line-level balanced analog audio outputs for driving external amplifiers or 
powered line arrays. The 1544ZOP integrates with AtlasIED’s GLOBALCOM.IP announcement controller. Optionally, the processed zone output audio 
may be routed back out over the network as Dante digital audio.

In addition to the four zone outputs, the 1544ZOP has four balanced line-level analog inputs that may be used as automated test inputs associated 
with the four zone outputs. Alternately, the analog inputs may be routed out over the network as Dante digital audio for such uses as for background 
music or auxiliary audio sources. 

The 1544ZOP also provides eight (8) logic inputs. Four of the inputs are standard closure detection and four are supervision capable, which provides 
the additional means to detect open or short conditions on the incoming links.

Inputs are provided for connecting up to eight (8) 540S ambient noise sensors (2 sensors for each output channel). This allows the output of each 
channel to be automatically adjusted in real time based on the measured ambient noise level in the zone.

Key Features

•  Four Balanced Line Level Audio Inputs
•  Four Balanced Line Level Audio Outputs
•  Four Standard Logic Inputs
•  Four Supervised Logic Inputs
•  Eight Ambient Sensor Inputs
•  Supports Audinate’s Dante™ Digital Network Audio
•  Compatible with AtlasIED GLOBALCOM

®

 Systems and 3rd Party Dante™ Devices

•  7-band Parametric EQ and a High-Pass and Low-Pass Filter Per Channel
•  Built-In Supervision of External Equipment or Speaker Lines May Be Configured
•  Fault Reports and Amplifier Status Available Over Ethernet Using Standard SNMP Protocol
•  LED Indicators for Power and Faults, Plus a Fault Relay (Form C)
•  Two Inputs for Ambient Noise Sensors for Each Amplifier Output Channel

Содержание 1544ZOP

Страница 1: ...er Trademarks are property of their respective owners No endorsement is implied Due to continual product development specifications are subject to change without notice ATS005966 RevA 5 19 DOC1227B AtlasIED com TELEPHONE 502 267 7436 SUPPORT ATLASIED COM 9701 TAYLORSVILLE ROAD LOUISVILLE KENTUCKY 40299 U S A 4x4 Smart Zone Output Processor 1544ZOP Installation Manual Version 0 3 Document 1227B ...

Страница 2: ...ns are subject to change without notice ATS005966 RevA 5 19 DOC1227B AtlasIED com TELEPHONE 502 267 7436 SUPPORT ATLASIED COM 9701 TAYLORSVILLE ROAD LOUISVILLE KENTUCKY 40299 U S A Table of Contents Important Safety Instructions 3 Introduction 8 Key Features 8 Front Panel Description 9 Rear Panel Description 9 Installing the 1544ZOP 10 Connecting Supervised Logic Inputs 11 Connecting Unbalanced Au...

Страница 3: ...for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 This product is equipped with a three wire groundi...

Страница 4: ... or electric shock may result Never operate this product or touch the power supply cord during an electrical storm electric shock may result Never exceed the power rating on the product when connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink ...

Страница 5: ...ecautions Personnel properly qualified in the application and use of life safety equipment qualified personnel shall read this manual carefully before performing any actions to specify apply install maintain and perform operational tests of AtlasIED systems and associated products in accordance with the instructions in this manual This manual shall be made available to all qualified personnel who ...

Страница 6: ...nd performed only by qualified personnel Whenever operation and maintenance is ongoing personnel in the equipment areas shall have an effective communication among these areas in order to protect people if any accident occurs Preliminary Precautions Precautions which are applicable to general electrical or electronic maintenance are as follows A Check yourself Wear no article that might catch on e...

Страница 7: ...sement Vérifier d abord si il y a un réseau de purgeur incorporé Si c est le cas attendez une minute ou deux pour que le condensateur se décharge par le réseau Sinon utilisez un réseau de décharge externe Ceci est très important en cas de haute tension ou des condensateurs à haute capacité Si un terminal est relié à la terre connecter le réseau de décharge entre l autre terminal et la terre Si auc...

Страница 8: ...four balanced line level analog inputs that may be used as automated test inputs associated with the four zone outputs Alternately the analog inputs may be routed out over the network as Dante digital audio for such uses as for background music or auxiliary audio sources The 1544ZOP also provides eight 8 logic inputs Four of the inputs are standard closure detection and four are supervision capabl...

Страница 9: ...nd B per channel may be connected If only one sensor is used per channel it can go into either the A or B position for the channel 2 Standard Logic Inputs These four inputs only detect open or closed circuit connections such as from dry contact closures Wetting voltage for inputs are supplied internally 3 Supervisable Logic Inputs These four inputs can be configured to detect shorts and opens in t...

Страница 10: ...ny accompanying components that may have been included The unit comes with a PA702 RMK kit of rack ears blank spacer and joining clips for easy mounting into a 19 rack The components of the rack mount kit are shown in the figure below The unit may be mounted either singly in a 19 rack using blank spacer and rack ears The unit can also be combined with a second 1544ZOP or compatible half rack unit ...

Страница 11: ...ced Audio Inputs Outputs The analog audio inputs outputs on the 1544ZOP are balanced On occasion it may be necessary to connect unbalanced audio devices to the 1544ZOP When doing this one should wire as shown in the figure below Connecting a Power Supply A suitable power supply should be connected to the rear connector being careful to observe the polarity shown on the connector Suitable power sup...

Страница 12: ...reen LED on Front Fault LED Yellow Amber LED on Front Network Connection LED Yellow LED on RJ 45 Connectors on Rear Network Data LED Green LED on RJ 45 Connectors on Rear Electrical Frequency Response 0 3 dB 20 Hz 20 kHz Unweighted Total Harmonic Distortion THD 0 01 20 Hz 20 kHz Unweighted Signal to Noise Ratio 90 dB 20 Hz 20 kHz Unweighted Line Level Inputs 6 dBu Max Line Level Outputs 6 dBu Max ...

Страница 13: ...ns 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equ...

Страница 14: ... when products have been modified or operated in excess of rated power altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to AtlasIED do not qualify for repair or replacement under our w...

Отзывы: