Precautions When Measuring High Voltage Potentials  

Observe the following precautions when measurements must be performed on circuits with potentials over 48 volts.

A.  Do not measure potentials over 48 volts without the presence or assistance of a person who is capable of rendering aid, and who is familiar with    
 

the procedure for emergency shutdown of the equipment.

B.  Be sure you are not grounded when you are adjusting equipment or using measuring equipment. Stand on a rubber mat or other insulator if  

 

 

possible. Be sure the equipment area is clean and dry. In general, use only one hand when servicing live equipment.

C.  If a test meter must be held or adjusted while voltage is applied, ground the case of the meter before starting a measurement. Do not touch the    
 

live equipment or personnel working on live equipment while holding the meter. The “common” terminal on some A/C electronic voltmeters is at    

 

ground potential; never connect the “common” terminal to any point above ground potential.

D.  High-voltage, high-capacitance capacitors should be discharged before servicing is started.

WARNING!

 Discharging must be done carefully and judiciously. First ascertain whether there is a built-in bleeder network. If so, wait a 

minute or two for the capacitor to discharge through the network. Otherwise, use an external discharge network. This is most important in 

the case of high voltage or high capacitance capacitors. If one terminal is connected to ground, connect the discharge network between the other 
terminal and ground. If neither terminal of the capacitor is grounded, connect the network across the capacitor terminals. Connecting a short circuit 
across the terminals is not recommended. Doing so can produce extremely high currents and a flash which can injure the eyes, vaporize metals, and 
cause burns.

AVERTISSEMENT:

 La décharge doit être faite soigneusement et judicieusement. Vérifier d’abord si il y a un réseau de purgeur incorporé. Si 

c’est le cas, attendez une minute ou deux pour que le condensateur se décharge par le réseau. Sinon, utilisez un réseau de décharge externe. 

Ceci est très important en cas de haute tension ou des condensateurs à haute capacité. Si un terminal est relié à la terre, connecter le réseau de 
décharge entre l’autre terminal et la terre. Si aucun terminal de condensateur est fondé, relier le réseau au terminal du condensateur. La connexion 
d’un court-circuit entre les terminaux n’est pas recommandée. Cela peut créé des courants très élevés où des étincelles pourrait blesser les yeux, 
fondre les métaux et causer des brûlures.

Precautions When Working on Energized Equipment 

When it is necessary to work on energized equipment, think ahead and anticipate every hazard. Never work alone on energized equipment.

Interlock switches are installed on some of the doors and panels to break the power circuits when the enclosure is entered. When it is necessary 
to work within such an enclosure on energized equipment, the interlock may be bypassed. Extreme caution should then be exercised, as dangerous 
voltages are present within the unit.

AC Power Circuits 

Equipment obtaining power from a secondary distribution system should be grounded at all times by means of a third grounding wire on the power 
lines. Equipment permanently wired to a secondary distribution system should also be grounded separately by connection to a grounding bus or 
ground rod with a sufficiently large conductor to handle the current expected if the secondary source is accidentally shorted to the equipment.

The ground wire should be protected from mechanical damage and periodically inspected for good physical condition.

Personnel should never depend on a switch to remove power from equipment. If the equipment is connected to the secondary distribution system by 
means of a power cable, detach the cable from the receptacle before attempting any repairs of removal of chassis.

If the equipment is permanently wired to the secondary distribution system, remove the main fuses or open the power switch. Attach a suitable 
warning tag to the switch which will warn personnel not to operate the equipment; only the person who originally attaches the warning tag should be 
authorized to remove it.

Resuscitation 

Personnel working with or near high voltage should be familiar with modern methods of resuscitation. Such information and training is available from 
the Red Cross or local emergency response personnel such as the police and fire department.

Содержание 1544ZOP

Страница 1: ...er Trademarks are property of their respective owners No endorsement is implied Due to continual product development specifications are subject to change without notice ATS005966 RevA 5 19 DOC1227B AtlasIED com TELEPHONE 502 267 7436 SUPPORT ATLASIED COM 9701 TAYLORSVILLE ROAD LOUISVILLE KENTUCKY 40299 U S A 4x4 Smart Zone Output Processor 1544ZOP Installation Manual Version 0 3 Document 1227B ...

Страница 2: ...ns are subject to change without notice ATS005966 RevA 5 19 DOC1227B AtlasIED com TELEPHONE 502 267 7436 SUPPORT ATLASIED COM 9701 TAYLORSVILLE ROAD LOUISVILLE KENTUCKY 40299 U S A Table of Contents Important Safety Instructions 3 Introduction 8 Key Features 8 Front Panel Description 9 Rear Panel Description 9 Installing the 1544ZOP 10 Connecting Supervised Logic Inputs 11 Connecting Unbalanced Au...

Страница 3: ...for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the device the device has been exposed to rain or moisture does not operate normally or has been dropped 15 This product is equipped with a three wire groundi...

Страница 4: ... or electric shock may result Never operate this product or touch the power supply cord during an electrical storm electric shock may result Never exceed the power rating on the product when connecting equipment Fire and or property damage may result Operate the product only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink ...

Страница 5: ...ecautions Personnel properly qualified in the application and use of life safety equipment qualified personnel shall read this manual carefully before performing any actions to specify apply install maintain and perform operational tests of AtlasIED systems and associated products in accordance with the instructions in this manual This manual shall be made available to all qualified personnel who ...

Страница 6: ...nd performed only by qualified personnel Whenever operation and maintenance is ongoing personnel in the equipment areas shall have an effective communication among these areas in order to protect people if any accident occurs Preliminary Precautions Precautions which are applicable to general electrical or electronic maintenance are as follows A Check yourself Wear no article that might catch on e...

Страница 7: ...sement Vérifier d abord si il y a un réseau de purgeur incorporé Si c est le cas attendez une minute ou deux pour que le condensateur se décharge par le réseau Sinon utilisez un réseau de décharge externe Ceci est très important en cas de haute tension ou des condensateurs à haute capacité Si un terminal est relié à la terre connecter le réseau de décharge entre l autre terminal et la terre Si auc...

Страница 8: ...four balanced line level analog inputs that may be used as automated test inputs associated with the four zone outputs Alternately the analog inputs may be routed out over the network as Dante digital audio for such uses as for background music or auxiliary audio sources The 1544ZOP also provides eight 8 logic inputs Four of the inputs are standard closure detection and four are supervision capabl...

Страница 9: ...nd B per channel may be connected If only one sensor is used per channel it can go into either the A or B position for the channel 2 Standard Logic Inputs These four inputs only detect open or closed circuit connections such as from dry contact closures Wetting voltage for inputs are supplied internally 3 Supervisable Logic Inputs These four inputs can be configured to detect shorts and opens in t...

Страница 10: ...ny accompanying components that may have been included The unit comes with a PA702 RMK kit of rack ears blank spacer and joining clips for easy mounting into a 19 rack The components of the rack mount kit are shown in the figure below The unit may be mounted either singly in a 19 rack using blank spacer and rack ears The unit can also be combined with a second 1544ZOP or compatible half rack unit ...

Страница 11: ...ced Audio Inputs Outputs The analog audio inputs outputs on the 1544ZOP are balanced On occasion it may be necessary to connect unbalanced audio devices to the 1544ZOP When doing this one should wire as shown in the figure below Connecting a Power Supply A suitable power supply should be connected to the rear connector being careful to observe the polarity shown on the connector Suitable power sup...

Страница 12: ...reen LED on Front Fault LED Yellow Amber LED on Front Network Connection LED Yellow LED on RJ 45 Connectors on Rear Network Data LED Green LED on RJ 45 Connectors on Rear Electrical Frequency Response 0 3 dB 20 Hz 20 kHz Unweighted Total Harmonic Distortion THD 0 01 20 Hz 20 kHz Unweighted Signal to Noise Ratio 90 dB 20 Hz 20 kHz Unweighted Line Level Inputs 6 dBu Max Line Level Outputs 6 dBu Max ...

Страница 13: ...ns 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equ...

Страница 14: ... when products have been modified or operated in excess of rated power altered serviced or installed in other than a workman like manner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to AtlasIED do not qualify for repair or replacement under our w...

Отзывы: