7.2 SELF-CALIBRATION
To access SELF-CALIBRATION menu, refer to Fig. 8.
For the self-calibration proceed as follows:
Make sure to entry the exact date of the wheel mounted. Entry of incorrect data
would mean that the machine is not correctly calibrated, therefore all
subsequent measurements will be incorrect until the new self-calibration is
performed with the correct data.
Fig. 18
Mount a wheel with average data on the shaft.
Entry the exact data of the wheel mounted.
Perform the first spin under normal condition
Rotate the wheel manually to 12 o’clock and apply 100g weight
on the inner side of the rim.
Start the second spin.
After the second spin, rotate the wheel manually to 12 o’clock and
apply 100g weight on the outer side of the rim.
Start the third spin.
After the spin,
flashes seconds to exit the weight
calibration automatically.
Remove the weights from the wheel.