Instruction Manual
1092 0381 48
43
3.3.6
Starting
Switch on the battery switch.
Switch the controller on by switching the Power switch to the position “ON”.
The instrument panel will now perform a selftest; the following display will be shown and the controller is
initialized:
During initializing all buttons/inputs/outputs/alarms are inactive.
This view will be shown for about 2 seconds, after which the display will show the Main View.
The actual vessel pressure is shown. If the measured vessel pressure is higher than 1.5 bar, the unit will
not start. The vessel pressure has to be lowered by opening the blow down valve. After power up, the
vessel pressure normally is low enough to proceed with the starting procedure.
The display now shows
If the Power switch is turned to the “OFF” position while the vessel is blowing down,
it will not power down for as long as the vessel pressure is higher than 1.5 bar.
Active Buttons
Measurement View Button
Settings View Button
Alarms View Button
Xc3003
v1.00.0 (r7307)
MAIN VIEW
VESSEL BLOWING DOWN
3.9
1200RPM
3.9bar
41%
1286h