41
Instruction Manual
8.3
C
OMPRESSOR
/E
NGINE
SPECIFICATIONS
1)
For aftercooler application: see APC- XII- Tab 17
2)
At reference conditions, if applicable, and at normal shaft speed, unless otherwise
stated.
3)
Data
Measured according to
Tolerance
Free air delivery
ISO 1217 ed.3
+/- 5% 25 l/s <FAD<250 l/s
1996 annex D
+/- 4% 250 l/s <FAD
The international standard ISO 1217 corresponds to following national standards:
- British BSI 1571 part 1
- German DIN 1945 Part 1
- Swedish SS-ISO 1217
- American ANSI PTC9
Free air delivery = volume flow rate
Compressor type
XAHS
XATS
XA(S)
XAVS
XAHS
146 Dd
156 Dd
186 Dd
166 Dd
186 Dd
Designation
Unit
Value
Value
Value
Value
Value
Reference conditions
1. Absolute inlet pressure
bar(e)
1
1
1
1
1
2. Relative air humidity
%
0
0
0
0
0
3. Air inlet temperature
°C
20
20
20
20
20
4. Nominal effective working pressure
bar(e)
12
10.3
7
14
12
The inlet conditions are specified at the
air inlet grating outside the canopy
Limitations
1. Minimum effective receiver pressure
bar(e)
4
4
4
4
4
2. Maximum effective receiver pressure,
compressor unloaded
bar(e)
13.5
11.8
8.5
15.5
13.5
3. Maximum ambient temperature at
sealevel
1)
°C
50
50
50
50
45
4. Minimum starting temperature
°C
- 10
- 10
- 10
- 10
- 10
5. Minimum starting temperature, with
coldstart equipment
°C
- 20
- 20
- 20
- 20
- 20
6. Altitude capability
m
5000
5000
5000
5000
5000
Performance data
2)
1. Engine shaft speed, normal and
maximum
r/min
2300
2300
2300
2300
2300
2. Engine shaft speed, compressor
unloaded
r/min
1700
1700
1700
1550
1550
3. Engine shaft speed, generator at
maximum load
r/min
-
-
-
-
-
4. Free air delivery
3)
l/s
141
166
185
158
175
5. Fuel consumption:
- at full load
kg/h
16.7
18.3
17.4
20.7
20.7
- at full load + generator
kg/h
-
-
-
-
-
- at unload
kg/h
8.3
9.6
8.5
12.4
12.4
6. Specific fuel consumption
g/m
3
32.9
30.3
26
33.8
33.8
7. Typical oil content of compressed air
mg/m
3
< 5
< 5
< 5
< 5
< 5
free air
8. Engine oil consumption (maximum)
g/h
14
14
14
14
62.1
9. Compressed air temperature at outlet
valves
°C
90
90
90
90
95
10. Noise level
- Sound pressure level (LP), measured
according to ISO 2151 under free
field conditions at 7 m distance
dB(A)
71
71
71
71
71
- Sound power level (LW) complies
with 2000/14/EC
dB(A)
99
99
99
99
99