The quantity of PARCOOL EG Concentrate to be topped up can be
estimated with the following formula and/or graph:
Corrections concentrate in measured system towards 50%
volume by using PARCOOL EG Concentrate
PN: 1604 8159 00
Example:
1
Refractometer indication -20° C (33%)
2
Refractometer indication -22° C
3
Refractometer indication -25° C
4
Refractometer indication -30° C
5
Refractometer indication -36° C
14
33
33
17
14
50
4,8
50-
=
=
*
/
Total volume coolant =
Measured concentration =
In case of expansion tank at low level, this quantity is to be filled
without draining from the cooling system.
Liter
Vol %
Liter PARCOOL EG Concentrate
4
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
5
6
7
8
9
10
11
12
13
14
15
16
1
2
3
4
5
Top-up volume PARCOOL EG Concentrate without drainage
Engine coolant capacity (liter)
Top
-up
volu
me (liter)