background image

Repair instruction No. 171.5/94

PB 14 D, PB 14 C

11

PAGE

11

Seite

 1

Press the liner (1) into the anvil
housing (2).

 

2

Grease the anvil (4) and replace the
O–rings (3) by new ones.

 

3

Insert the anvil into the anvil housing (2) (if
necessary tap it lightly with a hammer).
Ensure proper fit.

 

4

Fit the recoil ring (5), the recoil absorber
(6), the rubber ring (7), and the catcher
housing.

 1

Fit the slightly greased O–rings (6, 8 and
9) to the location ring (7).

 

2

Fit the location ring (7) to the hammer
case (10).

 

3

Fit the anvil assembly (5) over it, align it,
then place the nosepiece (3) on top.

 

4

Fit the anvil assembly and the nosepiece
to the hammer case (10) and secure them
with the six Allen screws (2).

 1

Fit the strap casting (4) to the guide nut (7)
of the hammer case and push the nose
cap (2) over of the strap casting.

 

2

Fit the circlip (1).

 

3

Expand the front handle (6) slightly and let
it engage over the strap casting (4).

 

4

Fit the screw (5) and the washer and
secure it tightly with the knob (3).

 1

Insert the latch bar (1) into the boring of
the nosepiece (2).

 

2

Place the spring cover (3), the spring (4),
and the latch retainer (5) on the latch bar
and press the latch bar into the nosepiece
by hitting the latch bar with a hammer.

Carry out a test run and check for strange noises.
Carry out an electrical test (see chapter Electrical and Mechanical Test Instruction).

Assembling the
anvil assembly

Fitting the anvil
assembly and
the nosepiece to
the hammer case

Assembling the
front handle
assembly

Fitting the tool
locking
mechanism

Test run and
electrical
examination

1

2

3 4

5 6 7 8

3

4

5

6

7

8 9

1

10

2

4

3

1

5

2

7

6

3

2

1

5

4

Содержание PB 14 C

Страница 1: ......

Страница 2: ...ersonnel with proper tools remove the liner 1 Remove the six Allen screws 1 together with the washers 2 Remove the hammer case 2 from the bearing housing 3 Attention Make sure you lose no parts that m...

Страница 3: ...rst remove the bearing clip 5 from the piston then take out the gudgeon pin 3 3 Remove the nu lip seal 2 with a screwdriver 1 Loosen the striker 1 by hitting the hammer case 4 lightly with a plastic h...

Страница 4: ...plate with a screwdriver and remove it 2 Lever off the handle support 3 with a screwdriver and remove the rear handle from the housing 3 Remove the handle support 3 and the handle support rubbers 2 fr...

Страница 5: ...ousing 2 and replace them by a pair of longer screws 3 The outer ring 1 is then pushed out from the bearing housing Maintenance It is recommended to submit the tool to maintenance after every 150 work...

Страница 6: ...After having dismantled the entire tool remove the used grease completely and replace by new grease For assembly a total of 350 g of grease is necessary Please pay attention to the following lubricat...

Страница 7: ...Before assembly make sure that the field location rubbers 6 fit properly in the field case 8 2 Insert the field coil 4 into the field case 8 3 Fit the baffle 3 to the field case 4 Replace the baffle...

Страница 8: ...leads are not jammed 5 Fit the support rubbers 2 and place the handle support 3 over it Take care that the leads are in the right position 6 Now replace the fitted rear handle assembly to the motor h...

Страница 9: ...2 Press the barrel in with aid of a service tool 3 Insert the barrel retainer 3 fit and secure it with three screws 4 1 Break the edges of the striker bearing clips 2 before fitting them to the strik...

Страница 10: ...earing assembly reception of the housing 1 as follows Concave sides facing downward 2 facing upward 2 facing downward 2 facing upward grease in between 2 Place the washer 3 on top of the springs 3 Ins...

Страница 11: ...to the guide nut 7 of the hammer case and push the nose cap 2 over of the strap casting 2 Fit the circlip 1 3 Expand the front handle 6 slightly and let it engage over the strap casting 4 4 Fit the sc...