Repair instruction No. 171.5/94
PB 14 D, PB 14 C
11
PAGE
11
Seite
1
Press the liner (1) into the anvil
housing (2).
2
Grease the anvil (4) and replace the
O–rings (3) by new ones.
3
Insert the anvil into the anvil housing (2) (if
necessary tap it lightly with a hammer).
Ensure proper fit.
4
Fit the recoil ring (5), the recoil absorber
(6), the rubber ring (7), and the catcher
housing.
1
Fit the slightly greased O–rings (6, 8 and
9) to the location ring (7).
2
Fit the location ring (7) to the hammer
case (10).
3
Fit the anvil assembly (5) over it, align it,
then place the nosepiece (3) on top.
4
Fit the anvil assembly and the nosepiece
to the hammer case (10) and secure them
with the six Allen screws (2).
1
Fit the strap casting (4) to the guide nut (7)
of the hammer case and push the nose
cap (2) over of the strap casting.
2
Fit the circlip (1).
3
Expand the front handle (6) slightly and let
it engage over the strap casting (4).
4
Fit the screw (5) and the washer and
secure it tightly with the knob (3).
1
Insert the latch bar (1) into the boring of
the nosepiece (2).
2
Place the spring cover (3), the spring (4),
and the latch retainer (5) on the latch bar
and press the latch bar into the nosepiece
by hitting the latch bar with a hammer.
Carry out a test run and check for strange noises.
Carry out an electrical test (see chapter Electrical and Mechanical Test Instruction).
Assembling the
anvil assembly
Fitting the anvil
assembly and
the nosepiece to
the hammer case
Assembling the
front handle
assembly
Fitting the tool
locking
mechanism
Test run and
electrical
examination
1
2
3 4
5 6 7 8
3
4
5
6
7
8 9
1
10
2
4
3
1
5
2
7
6
3
2
1
5
4
Содержание PB 14 C
Страница 1: ......