![Atlas Copco ORV 10 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/atlas-copco/orv-10/orv-10_instruction-manual_3001687030.webp)
28
ORV 10 - ORV 12 - ORX 10 - ORX 12
8.
TECHNICAL SPECIFICATIONS
8.1
R
EADINGS
ON
GAUGES
Gauge
Reading
Unit
Working pressure (PG2)
between unloading
and working
pressure
bar
below 6.5
bar
LP compressor element
air outlet temperature (TG1)
below 130
°C
HP compressor element
air outlet temperature (TG2)
below 130
°C
8.2
S
ETTINGS
OF
SWITCHES
AND
SAFETY
VALVE
Switch
Makes at
Breaks at
Shutdown switch
LP compressor element air outlet temperature
(TS1), adjustable up to
1)
-
130 °C
HP compressor element air outlet temperature
(TS2), adjustable up to
1)
-
130 °C
Alarm switch
Air filter vacuum indicator switch (VIS)
-
50 mbar
Start preventing pressure switch
0.5 +/- 0.4
1.5 +/- 0.3 bar(e)
Safety valve (SV)
Opening pressure
30 bar(e) (ORV)
34 bar(e) (ORX)
Minimum loading pressure switch
2.5 +/- 1
4.5 +/- 0.5 bar
1)
100°C for compressors for Germany.
Содержание ORV 10
Страница 1: ...ORV 10 ORV 12 ORX 10 ORX 12 Instruction Manual for Portable Compressors English ...
Страница 2: ......
Страница 43: ......
Страница 44: ...Printed in Belgium 11 2007 2954 3350 00 ...