![Atlas Copco ORV 10 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/atlas-copco/orv-10/orv-10_instruction-manual_3001687024.webp)
22
ORV 10 - ORV 12 - ORX 10 - ORX 12
4.5
C
LEANING
OIL
COOLER
Fig. 4.3
Compressor oil cooler
Keep the compressor oil cooler (1) clean to maintain the cooling
efficiency.
Steam cleaning in combination with a cleansing agent may be
applied.
The fan side surface of the cooler is accessible by removing the side
panels.
Install the side panels.
4.6
S
TORAGE
Run the compressor regularly, e.g. twice a week, until warm.
Load and unload the compressor a few times to operate the
unloading and regulating components. Close the air outlet valve(s)
after stopping.
4.7
S
ERVICE
KITS
A service kit is a collection of parts to fit a specific repair or
rebuilding task.
It guarantees that all necessary parts are replaced at the same time
which improves the uptime of the unit.
The order numbers of the Service Kits are listed in the Atlas Copco
Parts List (ASL).
4.8
C
OMPRESSOR
ELEMENT
OVERHAUL
When a compressor element is due for overhaul, it is recommended
to have it done by Atlas Copco. This guarantees the use of genuine
parts and correct tools with care and precision.
4.9
L
IABILITY
The manufacturer does not accept any liability for any damage
arising from the use of non-original parts and for modifications,
additions or conversions made without the manufacturer's approval
in writing.
To avoid damaging the coolers, angle between jet and
coolers should be approx. 90°
(do not use jet at max. power).
Never leave spilled liquids such as oil, water and
cleansing agents in or around the compressor.
(1)
If the compressor is going to be stored without running
from time to time, protective measures must be taken.
Contact Atlas Copco.