
- 70 -
P7........ Photocell sensitivity regulator
Is used for regulating the luminosity
sensitivity level of the photocell.
Setting the sensitivity regulator
The photocell sensitivity regulator is used for
regulating the luminosity sensitivity level of the
photocell.
When the red LED (1) on the regulator is blinking, the
regulator is reading the luminosity level measured by
the photocell.
There are 2 blinking levels:
– Level 1: slow blinking
The photocell detects there is enough light,
according to its set sensitivity level.
– Level 2: fast blinking
The photocell detects there is a prolonged
luminosity change that falls below the set
sensitivity level. Remote start will be triggered
and the floodlights of the light tower will switch
on automatically (if Remote start and Auto mode
are selected, see also chapter “Operating the light
tower” on page 29).
The recommended value to set the regulator is at
50 Lux.
– < 50 Lux: the floodlights switch on.
– > 50 Lux: the floodlights switch off.
The luminosity level can be adjusted to a desired
higher/lower level, according to the specific operating
conditions of the light tower.
ASM (Auto Rise and Lower Safety Mast)
The ASM option provides the possibility to not only
switch on/off the floodlights automatically, but also
to extend/lower the mast automatically.
To enable automatic mast operation, proceed as
follows:
1. Put the starter switch S20 in position REMOTE.
2. Switch ON the 4 circuit breakers (Q2-5).
3. Put the auto positioning switch S25 in position
AUTO.
4. Push the AUTO button on the Lc1003™ module
(1) to activate AUTO mode.
5. A remote start signal (Sunset or Weekly timer
start) will trigger the following actions:
• Start engine
• Activate buzzer
• Rise mast
• Sequence lamp start
S50
S51
S20
0
1
H16
Q2
Q3
Q4
Q5
Q1
Q6
P7
AUTO MAN
AUTO MAN
P7
A1 A2 12
50
75
100
25
1
LX
11 14
B1 B2
1
Before activating the ASM option,
make sure that the lighting tower is
properly positioned, away from
overhead power cables or other
obstructions.
S50
S51
S20
0
1
H16
Q2
Q3
Q4
Q5
Q1
Q6
P7
AUTO MAN
F10
AUTO MAN
Q2-5
S20
1
P7
S25
00_00_HiLight H6+_EN.book Page 70 Friday, June 4, 2021 11:52 AM
Содержание HiLight H6+ DC
Страница 2: ...00_00_HiLight H6 _EN book Page 2 Friday June 4 2021 11 52 AM ...
Страница 93: ... 93 10 6 Dimensions ON ROAD UNDERCARRIAGE LED 00_00_HiLight H6 _EN book Page 93 Friday June 4 2021 11 52 AM ...
Страница 94: ... 94 ON ROAD UNDERCARRIAGE LED 00_00_HiLight H6 _EN book Page 94 Friday June 4 2021 11 52 AM ...
Страница 96: ... 96 00_00_HiLight H6 _EN book Page 96 Friday June 4 2021 11 52 AM ...
Страница 97: ... 97 Circuit diagrams 00_00_HiLight H6 _EN book Page 97 Friday June 4 2021 11 52 AM ...
Страница 112: ... 112 00_00_HiLight H6 _EN book Page 112 Friday June 4 2021 11 52 AM ...
Страница 115: ...00_00_HiLight H6 _EN book Page 115 Friday June 4 2021 11 52 AM ...
Страница 116: ...Printed in Spain www atlascopco com 00_00_HiLight H6 _EN book Page 116 Friday June 4 2021 11 52 AM ...