9
Instructions for use
Oil separator vessel
1
The vessel can contain pressurised air. This can be potentially dangerous if the equipment
is misused.
2
This vessel must only be used as a compressed air/oil separator tank and must be
operated within the limits specified on the data plate.
3
No alterations must be made to this vessel by welding, drilling or other mechanical methods
without the written permission of the manufacturer.
4
The pressure and temperature of this vessel must be clearly indicated.
5
The safety valve must correspond with pressure surges of 1.1 times the maximum
allowable operating pressure. It should guarantee that the pressure will not permanently
exceed the maximum allowable operating pressure of the vessel.
6
Use only oil as specified by the manufacturer.
7
In case of misuse of the units (frequent operation with too low oil temperature or long
interval of shut down), a certain amount of condensate can gather in the oil separator
vessel which must be properly drained. To do so, disconnect the unit from the power line,
wait till it is cooled down and depressurised and drain the water by the oil drain valve,
positioned at the bottom side of the oil separator vessel.
Local legislation may require an periodic inspection.
Air receiver (on tank-mounted units)
1
Corrosion must be prevented: depending on the conditions of use, condensate may
accumulate inside the tank and must be drained every day.
This may be done
manually by opening the drain valve, or by means of the automatic drain, if fitted to the
tank. Nevertheless, a weekly check of correct functioning of the automatic valve is needed.
This has to be done by opening the manual drain valve and check for condensate. Verify
that no rust obstructions affect the drain system.
2
Yearly service inspection of the air receiver is needed, as internal corrosion can
reduce the steel wall thickness with the consequent risk of bursting
. Local rules need
to be respected, if applicable. The use of the air receiver is forbidden once the wall
thickness reaches the minimum value as indicated in the service manual of the air receiver
(part of the documentation delivered with the unit).
3
Lifetime of the air receiver mainly depends on the working environment. Installing the
compressor in a dirty and corrosive environment is not allowed, as this can reduce the
vessel lifetime dramatically.
4
Do not anchor the vessel or attached components directly to the ground or fixed structures.
Fit the pressure vessel with vibration dampers to avoid possible fatigue failure caused by
vibration of the vessel during use.
5
Use the vessel within the pressure and temperature limits stated on the nameplate and
the testing report.
6
No alterations must be made to this vessel by welding, drilling or other mechanical
methods.
Instruction book
2920 7105 31
67
Содержание GX 2 EP
Страница 2: ......
Страница 13: ...2 2 Air flow Pack Air flow floor mounted Pack units Instruction book 2920 7105 31 11 ...
Страница 16: ...2 3 Oil system GX Pack Instruction book 14 2920 7105 31 ...
Страница 18: ...2 4 Cooling system Pack units Instruction book 16 2920 7105 31 ...
Страница 27: ...GX 7 EP IEC units with Y D start Instruction book 2920 7105 31 25 ...
Страница 28: ...GX 7 EP for 208 230 460V 60 Hz DOL Instruction book 26 2920 7105 31 ...
Страница 37: ...GX 7 EP Pack on 200l receiver 2 Cooling air inlet Instruction book 2920 7105 31 35 ...
Страница 59: ...7 Problem solving Air outlet valve Dryer on off switch GX Full Feature Instruction book 2920 7105 31 57 ...
Страница 74: ......
Страница 75: ......