Air flow, tank-mounted Pack units
Air drawn in through air filter (AF) and open inlet valve (IV) is compressed in compressor element (E).
Compressed air and oil flow into oil separator/tank (OT) where most of the oil is removed by centrifugal
action. The remaining oil is removed by oil separator (OS). The air flows to the outlet (AO) via minimum
pressure valve (Vp).
Instruction book