(4)
Menu
(5)
Running Hours
(6)
Element Outlet
(7)
Load
,
Unload
, ... (text varies upon the compressors actual condition)
•
Section A
shows information regarding the compressor operation (e.g. the outlet pressure or the
temperature at the compressor outlet).
•
Section B
shows Status icons. Following icon types are shown in this field:
• Fixed icons
These icons are always shown in the main screen and cannot be selected by the cursor (e.g.
Compressor stopped or running, Compressor status (running, running unloaded or motor
stopped).
• Optional icons
These icons are only shown if their corresponding function is activated (e.g. week timer,
automatic restart after voltage failure , etc.)
• Pop up icons
These icons pop up if an abnormal condition occurs (warnings, shutdowns, service,...)
To call up more information about the icons shown, select the icon concerned using the scroll keys
and press the enter key.
•
Section C
is called the Status bar
This bar shows the text that corresponds to the selected icon.
•
Section D
shows the Action buttons. These buttons are used:
• To call up or program settings
• To reset a motor overload, service message or emergency stop
• To have access to all data collected by the regulator
The function of the buttons depends on the displayed menu. The most common functions are:
Designation
Function
Menu
To go to the menu
Modify
To modify programmable settings
Reset
To reset a timer or message
To activate an action button, highlight the button by using the Scroll keys and press the Enter key.
To go back to the previous menu, press the Escape key.
Chart views
) in function of the time.
Instruction book