Regularly check the oil level. To do this, press the stop button (9). Three minutes after stopping, sight glass
(Gl) should be between 1/4 and 3/4 full.
If the oil level is too low, press the emergency stop button (10), close the air outlet valve and open (if
provided) the manual condensate drains. Next, depressurize the oil system by unscrewing oil filler plug
(FC) one turn and wait a few minutes. Remove the plug and top up oil, until the sight glass is full. Fit and
tighten the filler plug.
Position of oil level sight glass
On compressors with an Elektronikon® controller, unlock the emergency stop button (10) and press the
reset button (5) before restarting.
On compressors with an Elektronikon® Graphic controller, unlock the emergency stop button (10), select
the STOP icon on the display and press reset before restarting.
Air filter
Especially if the compressor is installed in a dusty environment, inspect the air filter element regularly.
Replace when necessary. See also
Preventive maintenance schedule
for periodic replacement instructions.
Drains
Regularly check that condensate is discharged during operation. See section. The amount of condensate
depends on environmental and working conditions.
Instruction book
130
2920 7140 90
Содержание GA15
Страница 1: ...Atlas Copco Oil injected rotary screw compressors GA 15 GA 18 GA 22 GA 26 Instruction book ...
Страница 2: ......
Страница 47: ...7 20 Calling up modifying pressure band settings Calling up the settings Instruction book 2920 7140 90 45 ...
Страница 168: ......
Страница 169: ......