4.9
Installation instructions GSM alarm
Hardware installation
Fix the Air contact module (1) to the rail as shown below.
Assemble the power supply cable, using:
• connector X150.3 (ordering number 1088 0037 64)
• two power wires (ordering number 0017 2010 40)
• one earth wire (ordering number 0017 2070 40)
• connector 12X14 (ordering number 1088 0037 62; the connector is supplied loose with the Air contact
module)
Install the power supply cable, plug the 3 pole connector (12X14) (4) in the Air contact module.
Plug the LAN cable (1622 0676 20) (3) into the Elektronikon (Mk4) and in the Aircontact module (5).